Polarimetric Balanced Detection: Background-Free Mid-IR Evanescent Field Laser Spectroscopy for Low-Noise, Long-term Stable Chemical Sensing.

Stephan Freitag, Matthias Baer, Laura Buntzoll, Georg Ramer, Andreas Schwaighofer, Bernhard Schmauss, Bernhard Lendl

Abstract read
In one paragraph

Article in ACS sensors, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Resolution Limit in Infrared Chemical Imaging.The journal of physical chemistry. C, Nanomaterials and interfaces · 2022
    Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Stephan FreitagInstitute of Chemical Technologies and Analytics, Technische Universität Wien, Getreidemarkt 9/164-UPA, 1060 Vienna, Austria.ORCID 0000-0003-0179-2217
Matthias BaerInstitute of Microwaves and Photonics, Friedrich-Alexander-University Erlangen-Nuremberg, Cauerstr. 9, 91058 Erlangen, Germany.
Laura BuntzollInstitute of Microwaves and Photonics, Friedrich-Alexander-University Erlangen-Nuremberg, Cauerstr. 9, 91058 Erlangen, Germany.
Georg RamerInstitute of Chemical Technologies and Analytics, Technische Universität Wien, Getreidemarkt 9/164-UPA, 1060 Vienna, Austria.ORCID 0000-0001-8307-5435
Andreas SchwaighoferInstitute of Chemical Technologies and Analytics, Technische Universität Wien, Getreidemarkt 9/164-UPA, 1060 Vienna, Austria.ORCID 0000-0003-2714-7056
Bernhard SchmaussInstitute of Microwaves and Photonics, Friedrich-Alexander-University Erlangen-Nuremberg, Cauerstr. 9, 91058 Erlangen, Germany.
Bernhard LendlInstitute of Chemical Technologies and Analytics, Technische Universität Wien, Getreidemarkt 9/164-UPA, 1060 Vienna, Austria.ORCID 0000-0003-3838-5842

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In this work, we introduce polarimetric balanced detection as a new attenuated total reflection (ATR) infrared (IR) sensing scheme, leveraging unequal effective thicknesses achieved with laser light of different polarizations. We combined a monolithic widely tunable Vernier quantum cascade laser (QCL-XT) and a multibounce ATR IR spectroscopy setup for analysis of liquids in a process analytical setting. Polarimetric balanced detection enables simultaneous recording of background and sample spectra, significantly reducing long-term drifts. The root-mean-square noise could be improved by a factor of 10 in a long-term experiment, compared to conventional absorbance measurements obtained via the single-ended optical channel. The sensing performance of the device was further evaluated by on-site measurements of ethanol in water, leading to an improved limit of detection (LOD) achieved with polarimetric balanced detection. Sequential injection analysis was employed for automated injection of samples into a custom-built ATR flow cell mounted above a zinc sulfide multibounce ATR element. The QCL-XT posed to be suitable for mid-IR-based sensing in liquids due to its wide tunability. Polarimetric balanced detection proved to enhance the robustness and long-term stability of the sensing device, along with improving the LOD by a factor of 5. This demonstrates the potential for new polarimetric QCL-based ATR mid-IR sensing schemes for in-field measurements or process monitoring usually prone to a multitude of interferences.

Indexed as

Lasers, SemiconductorWaterSpectrophotometry, InfraredWaterattenuated total reflectionbalanced detectionmid-infrared spectroscopyprocess analytical technologyquantum cascade lasers

Identifiers

PMID33372759
PMCPMC7872502

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.