Evidence map›Paper›PMID 33372354›Full record

ArticleVeterinary and comparative oncology2021

Reducing margins for abdominopelvic tumours in dogs: Impact on dose-coverage and normal tissue complication probability.

Valeria Meier, Chris Staudinger, Stephan Radonic, Jürgen Besserer, Uwe Schneider, Linda Walsh, Carla Rohrer Bley

Open access · hybridAbstract read
In one paragraph

Article in Veterinary and comparative oncology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.0field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Valeria MeierDivision of Radiation Oncology, Small Animal Department, Vetsuisse Faculty, University of Zurich, Zurich, Switzerland.ORCID https://orcid.org/0000-0003-0793-9005
Chris StaudingerDivision of Radiation Oncology, Small Animal Department, Vetsuisse Faculty, University of Zurich, Zurich, Switzerland.ORCID https://orcid.org/0000-0002-5536-2733
Stephan RadonicDivision of Radiation Oncology, Small Animal Department, Vetsuisse Faculty, University of Zurich, Zurich, Switzerland.
Jürgen BessererDivision of Radiation Oncology, Small Animal Department, Vetsuisse Faculty, University of Zurich, Zurich, Switzerland.
Uwe SchneiderDivision of Radiation Oncology, Small Animal Department, Vetsuisse Faculty, University of Zurich, Zurich, Switzerland.
Linda WalshDepartment of Physics, University of Zurich, Zurich, Switzerland.
Carla Rohrer BleyDivision of Radiation Oncology, Small Animal Department, Vetsuisse Faculty, University of Zurich, Zurich, Switzerland.ORCID https://orcid.org/0000-0002-5733-2722
University of Zurich · CH

Funding

Swiss National Science Foundation (SNSF) 320030-182490
6 · The paper itself

Abstract

Image-guided, intensity modulated radiation therapy (IG-IMRT) reduces dose to pelvic organs at risk without losing dose coverage to the planning target volume (PTV) and might permit margin reductions potentially resulting in lower toxicity. Appropriate PTV margins have not been established for IG-IMRT in abdominopelvic tumours in dogs, and herein we explore if our usual PTV 5 mm margin can be reduced further. Datasets from dogs that underwent IG-IMRT for non-genitourinary abdominopelvic neoplasia with 5 mm-PTV expansion were included in this retrospective virtual study. The clinical target volumes and organs at risk (OAR) colon, rectum, spinal cord were adapted to each co-registered cone-beam computed tomography (CBCT) used for positioning. New treatment plans were generated and smaller PTV margins of 3 mm and 4 mm evaluated with respect to adequate dose coverage and normal tissue complication probability (NTCP) of OAR. Ten dogs with a total of 70 CBCTs were included. Doses to the OAR of each CBCT deviated mildly from the originally planned doses. In some plans, insufficient build-up of the high dose-area at the body surface was found due to inadequate or missing bolus placement. Overall, the margin reduction to 4 mm or 3 mm did not impair dose coverage and led to significantly lower NTCP in all OAR except for spinal cord delayed myelopathy. However, overall NTCP for spinal cord was very low (<4%). PTV-margins depend on patient immobilization and treatment technique and accuracy. IG-IMRT allows treatment with very small margins in the abdominopelvic region, ensuring appropriate target dose coverage, while minimizing NTCP.

Indexed as

Dog DiseasesProstatic NeoplasmsRadiotherapy, Intensity-ModulatedAnimalsDogsMaleProbabilityRadiotherapy DosageRadiotherapy Planning, Computer-AssistedRetrospective Studiesanal gland adenocarcinomaIGRTIMRTplanning target volumePTVradiation therapy

Identifiers

PMID33372354
PMCPMC8247346
OpenAlexW3114404624

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.