Evidence map›Paper›PMID 33371623›Full record

ArticleAsian spine journal2021

Surgical Invasiveness of Single-Segment Posterior Lumbar Interbody Fusion: Comparing Perioperative Blood Loss in Posterior Lumbar Interbody Fusion with Traditional Pedicle Screws, Cortical Bone Trajectory Screws, and Percutaneous Pedicle Screws.

Tetsuji Inoue, Masaya Mizutamari, Kuniaki Hatake

Open access · diamondAbstract read
In one paragraph

Article in Asian spine journal, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 1 pooled it
0.9field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 1 synthesis or guideline pooled it, 10 citations in OpenAlex.

  1. Pooled it
  2. Review
  3. Article
  4. Article
  5. Review
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Tetsuji InoueDepartment of Orthopaedic Surgery, Kumamoto Chuo Hospital, Kumamoto, Japan.
Masaya MizutamariDepartment of Orthopaedic Surgery, Kumamoto Chuo Hospital, Kumamoto, Japan.
Kuniaki HatakeDepartment of Orthopaedic Surgery, Kumamoto Chuo Hospital, Kumamoto, Japan.
Saiseikai Kumamoto Hospital · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

STUDY

designSingle-center retrospective study. PURPOSE: This study aims to evaluate the surgical invasiveness of single-segment posterior lumbar interbody fusion (PLIF) by comparing perioperative blood loss in PLIF with traditional pedicle screws (PS), cortical bone trajectory screws (CBT), and percutaneous pedicle screws (PPS). OVERVIEW OF LITERATURE: Intraoperative blood loss has often been used to evaluate surgical invasiveness. However, in patients undergoing spinal surgery, more blood loss is observed postoperatively than intraoperatively. Therefore, evaluating surgical invasiveness using only the intraoperative bleeding volume may result in considerable underestimation of the actual surgical invasiveness.

methodsThis study included patients who underwent single-segment PLIF between January 2012 and December 2017. In total, seven patients underwent PLIF with PS (PS-PLIF), nine underwent PLIF with CBT (CBT-PLIF), and 15 underwent PLIF with PPS (PPS-PLIF).

resultsNo significant differences were noted in terms of operation time or intraoperative bleeding between the PS-PLIF, CBT-PLIF, and PPS-PLIF groups. However, the postoperative drainage volume in the PPS-PLIF group (210.1 mL; range, 50-367 mL) was determined to be significantly lower than that in the PS-PLIF (416.7 mL; range, 260-760 mL; p=0.002) and CBT-PLIF (421.1 mL; range, 180-890 mL; p=0.006) groups. In addition, the total amount of intraoperative bleeding and postoperative drainage was found to be significantly lower in the PPS-PLIF group (362.8 mL; range, 145-637 mL) than in the PS-PLIF (639.6 mL; range, 285-1,000 mL; p=0.01) and CBT-PLIF (606.7 mL; range, 270-950 mL; p=0.005) groups.

conclusionsBased on our findings, evaluating surgical invasiveness using only intraoperative bleeding can result in the underestimation of actual surgical invasiveness. Even with single-segment PLIF, the amount of perioperative bleeding can vary depending on the way the posterior instrument is installed.

Indexed as

Percutaneous pedicle screwPerioperative bleedingPosterior lumbar interbody fusionPostoperative bleedingSpine surgical invasiveness

Identifiers

PMID33371623
PMCPMC8696064
OpenAlexW3116632400

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.