ArticleSensors (Basel, Switzerland)2020
Swept-Source-Based Chromatic Confocal Microscopy.
Article in Sensors (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 10 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 1 country.
Funding
Abstract
Chromatic confocal microscopy (CCM) has been intensively developed because it can exhibit effective focal position scanning based on the axial chromatic aberration of broadband light reflected from a target. To improve the imaging speed of three-dimensional (3D) surface profiling, we have proposed the novel concept of swept-source-based CCM (SS-CCM) and investigated the usefulness of the corresponding imaging system. Compared to conventional CCM based on a broadband light source and a spectrometer, a swept-source in the proposed SS-CCM generates light with a narrower linewidth for higher intensity, and a single photodetector employed in the system exhibits a fast and sensitive response by immediately obtaining spectrally encoded depth from a chromatic dispersive lens array. Results of the experiments conducted to test the proposed SS-CCM system indicate that the system exhibits an axial chromatic focal distance range of approximately 360 μm for the 770-820 nm swept wavelength range. Moreover, high-speed surface profiling images of a cover glass and coin were successfully obtained with a short measurement time of 5 ms at a single position.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.