Evidence map›Paper›PMID 33369069›Full record

ArticleThe international journal of medical robotics + computer assisted surgery : MRCAS2021

Improving MiniHip femoral prosthesis positioning using a cross-laser projection system in total hip arthroplasty by an anterolateral supine approach.

Hideki Fujii, Tetsuo Hayama, Toshiomi Abe, Motoi Takahashi, Yohei Matsushita, Ryuichi Sato, Takuya Otani, Mitsuru Saito

Open access · hybridAbstract read
In one paragraph

Article in The international journal of medical robotics + computer assisted surgery : MRCAS, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact, top 73% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Hideki FujiiDepartment of Orthopaedic Surgery, The Jikei University School of Medicine, Tokyo, Japan.ORCID https://orcid.org/0000-0001-8985-6312
Tetsuo HayamaDepartment of Orthopaedic Surgery, The Jikei University School of Medicine, Tokyo, Japan.
Toshiomi AbeDepartment of Orthopaedic Surgery, The Jikei University School of Medicine, Tokyo, Japan.
Motoi TakahashiDepartment of Orthopaedic Surgery, The Jikei University School of Medicine, Tokyo, Japan.
Yohei MatsushitaDepartment of Orthopaedic Surgery, The Jikei University School of Medicine, Tokyo, Japan.
Ryuichi SatoDepartment of Orthopaedic Surgery, The Jikei University School of Medicine, Tokyo, Japan.
Takuya OtaniDepartment of Orthopaedic Surgery, The Jikei University School of Medicine, Tokyo, Japan.
Mitsuru SaitoDepartment of Orthopaedic Surgery, The Jikei University School of Medicine, Tokyo, Japan.
Jikei University School of Medicine · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe authors developed a cross-laser projection system (CLP) to place a femoral neck-sparing short stem using the minimally invasive anterolateral supine approach in total hip arthroplasty. This study aimed to verify the utility of CLP.

methodsThirty joints were assessed with the MiniHip (Corin). The authors compared femoral component implantation with a patient-specific femoral osteotomy guide (PSG) for the femoral neck-cut (PSG group), with the CLP attached to the rasp handle to irradiate the cross-laser to the target of PSG (CLP group), and without PSG or CLP (control group).

resultsIn the CLP group, the positional deviation of anteversion, anterior/posterior tilt and varus/valgus placement of the stem postoperatively were 1.8° ± 0.2°, 2.0° ± 2.0° and 2.0° ± 0.1°, respectively. The positional deviation of anteversion (p < 0.001) and anterior/posterior tilt (p = 0.036) were significantly smaller than those in the other groups.

conclusionsCLP improves the accuracy of MiniHip femoral prosthesis placement.

Indexed as

Arthroplasty, Replacement, HipHip ProsthesisFemaleFemurFemur NeckHumansMaleMiddle AgedProsthesis Designanterolateral supine approachhip arthroplastyMiniHipminimally invasive surgerypatient-specificshort stem

Identifiers

PMID33369069
PMCPMC7988605
OpenAlexW3113749534

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.