ArticleJournal of applied clinical medical physics2021
Using patient-specific bolus for pencil beam scanning proton treatment of periorbital disease.
Article in Journal of applied clinical medical physics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed, 12 citations in OpenAlex.
- Evaluations of Penumbra Reduction Using Multi-Leaf Collimator and 3D Bolus in Scanned Proton Therapy.International journal of particle therapy · 2026Article
- Enhancing proton therapy for superficial lesions using patient-specific bolus and multi-leaf collimator.Radiological physics and technology · 2026Article
- Article
- Clinical Viability of an Active Spot Scanning Beam Delivery System With a Newly Developed Carbon-Ion Treatment Planning System.Advances in radiation oncology · 2024Article
- Article
- Advances in treatment planning and management for the safety and accuracy of lung stereotactic body radiation therapy using proton pencil beam scanning: Simulation, planning, quality assurance, and delivery recommendations.Journal of radiosurgery and SBRT · 2023Article
- Treatment of ocular tumors through a novel applicator on a conventional proton pencil beam scanning beamline.Scientific reports · 2022Article
- Dose rate and dose robustness for proton transmission FLASH-RT treatment in lung cancer.Frontiers in oncology · 2022Article
- Applications of various range shifters for proton pencil beam scanning radiotherapy.Radiation oncology (London, England) · 2021Article
- Bilateral Lacrimal Gland Mantle Cell Lymphoma in 11-Year Follow-Up: Case Report and Review of 48 Cases With Ocular Adnexal Presentation in the Literature.Journal of investigative medicine high impact case reportsArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeA unique mantle cell lymphoma case with bilateral periorbital disease unresponsive to chemotherapy and with dosimetry not conducive to electron therapy was treated with pencil beam scanning (PBS) proton therapy. This patient presented treatment planning challenges due to the thin target, immediately adjacent organs at risk (OAR), and nonconformal orbital surface anatomy. Therefore, we developed a patient-specific bolus and hypothesized that it would provide superior setup robustness, dose uniformity and dose conformity. MATERIALS/
methodsA blue-wax patient-specific bolus was generated from the patient's face contour to conform to his face and eliminate air gaps. A relative stopping power ratio (RSP) of 0.972 was measured for the blue-wax, and the HUs were overridden accordingly in the treatment planning system (TPS). Orthogonal kV images were used for bony alignment and then to ensure positioning of the bolus through fiducial markers attached to the bolus and their contours in TPS. Daily CBCT was used to confirm the position of the bolus in relation to the patient's surface. Dosimetric characteristics were compared between (a) nonbolus, (b) conventional gel bolus and (c) patient-specific bolus plans. An in-house developed workflow for assessment of daily treatment dose based on CBCT images was used to evaluate inter-fraction dose accumulation.
resultsThe patient was treated to 24 cobalt gray equivalent (CGE) in 2 CGE daily fractions to the bilateral periorbital skin, constraining at least 50% of each lacrimal gland to under 20 Gy. The bolus increased proton beam range by adding 2-3 energy layers of different fields to help achieve better dose uniformity and adequate dose coverage. In contrast to the plan with conventional gel bolus, dose uniformity was significantly improved with patient-specific bolus. The global maximum dose was reduced by 7% (from 116% to 109%). The max and mean doses were reduced by 6.0% and 7.7%, respectively, for bilateral retinas, and 3.0% and 13.9% for bilateral lacrimal glands. The max dose of the lens was reduced by 2.1%. The rigid shape, along with lightweight, and smooth fit to the patient face was well tolerated and reported as "very comfortable" by the patient. The daily position accuracy of the bolus was within 1 mm based on IGRT marker alignment. The daily dose accumulation indicates that the target coverage and OAR doses were highly consistent with the planning intention.
conclusionOur patient-specific blue-wax bolus significantly increased dose uniformity, reduced OAR doses, and maintained consistent setup accuracy compared to conventional bolus. Quality PBS proton treatment for periorbital tumors and similar challenging thin and shallow targets can be achieved using such patient-specific bolus with robustness on both setup and dosimetry.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.