Evidence map›Paper›PMID 33368998›Full record

ArticleJournal of applied clinical medical physics2021

Effect of obesity on ability to lower exposure for detection of low-attenuation liver lesions.

Brian R Herts, Andrew Schreiner, Frank Dong, Andrew Primak, Jennifer Bullen, Wadih Karim, Douglas Nachand, Sara Hunter, Mark E Baker

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Brian R HertsCleveland Clinic, Imaging Institute - Desk L10, Cleveland, OH, USA.ORCID https://orcid.org/0000-0002-7408-0248
Andrew SchreinerCleveland Clinic, Imaging Institute - Desk L10, Cleveland, OH, USA.
Frank DongDepartment of Medical Physics - Desk AC-211, Cleveland Clinic, Imaging Institute, Beachwood, OH, USA.
Andrew Primakc/o Imaging Institute - Desk AC-221, Siemens Healthineers, Beachwood, OH, USA.
Jennifer BullenDepartment of Quantitative Health Sciences - JJN3, Cleveland Clinic, Cleveland, OH, USA.
Wadih KarimCleveland Clinic, Imaging Institute - Desk L10, Cleveland, OH, USA.
Douglas NachandCleveland Clinic, Imaging Institute - Desk L10, Cleveland, OH, USA.
Sara HunterCleveland Clinic, Imaging Institute - Desk L10, Cleveland, OH, USA.
Mark E BakerCleveland Clinic, Imaging Institute - Desk L10, Cleveland, OH, USA.ORCID https://orcid.org/0000-0001-5023-3361

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe purpose of this study was to assess the effect of obesity and iterative reconstruction on the ability to reduce exposure by studying the accuracy for detection of low-contrast low-attenuation (LCLA) liver lesions on computed tomography (CT) using a phantom model.

methodsA phantom with four unique LCLA liver lesions (5- to 15-mm spheres, -24 to -6 HU relative to 90-HU background) was scanned without ("thin" phantom) and with ("obese" phantom) a 5-cm thick fat-attenuation ring at 150 mAs (thin phantom) and 450 mAs (obese phantom) standard exposures and at 33% and 67% exposure reductions. Images were reconstructed using standard filtered back projection (FBP) and with iterative reconstruction (Adaptive Model-Based Iterative Reconstruction strength 3, ADMIRE). A noninferiority analysis of lesion detection was performed.

resultsMean area under the curve (AUC) values for lesion detection were significantly higher for the thin phantom than for the obese phantom regardless of exposure level (P < 0.05) for both FBP and ADMIRE. At 33% exposure reduction, AUC was noninferior for both FBP and ADMIRE strength 3 (P < 0.0001). At 67% exposure reduction, AUC remained noninferior for the thin phantom (P < 0.0035), but was no longer noninferior for the obese phantom (P ≥ 0.7353). There were no statistically significant differences in AUC between FBP and ADMIRE at any exposure level for either phantom.

conclusionsAccuracy for lesion detection was not only significantly lower in the obese phantom at all relative exposures, but detection accuracy decreased sooner while reducing the exposure in the obese phantom. There was no significant difference in lesion detection between FBP and ADMIRE at equivalent exposure levels for either phantom.

Indexed as

AlgorithmsLiver NeoplasmsHumansObesityPhantoms, ImagingRadiation DosageRadiographic Image Interpretation, Computer-Assistedcomputed tomographyiterative reconstructionlow dose

Identifiers

PMID33368998
PMCPMC7882113

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.