Evidence map›Paper›PMID 33363352›Full record

ArticleVeterinary world2020

Coagulation testing: Comparison of portable (CoaguChek

Sireeporn Tonthong, Jetsada Rungpupradit

Open access · goldAbstract read
In one paragraph

Article in Veterinary world, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact, top 81% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Sireeporn TonthongDepartment of Small Domestic Animal and Radiology, Faculty of Veterinary Medicine, Mahanakorn University of Technology, Bangkok, Thailand.
Jetsada RungpupraditDepartment of Small Domestic Animal and Radiology, Faculty of Veterinary Medicine, Mahanakorn University of Technology, Bangkok, Thailand.
Mahanakorn University of Technology · TH

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND AND

aimThe CoaguChek MATERIALS AND

methodsBlood samples of 82 cats were collected from the jugular vein and PT was measured using both the CCX and an automated coagulation analyzer (ACA). Spearman's correlation was used to measure the strength and direction of association between the two analyzers, while limits of agreement were assessed utilizing Bland-Altman analysis.

resultsRange of PT using the CCX was 10.1-14.1 s. Correlation between the two analyzers was moderate but significant (r=0.3465, p=0.0014). Mean difference between CCX-PT and ACA-PT was 1.624 s and standard deviation was 0.890 with 95.1% of the samples falling within the limits of agreement.

conclusionThe CCX is a portable, easy to use coagulation analyzer that requires a small volume of blood and gives results within 1 min. Results showed moderate correlation and good agreement with a standard automated laboratory analyzer. The CCX can be used for screening coagulation testing when PT is in the normal range for cats. However, testing accuracy of the CCX in abnormal PT cats should be further investigated before diagnostic coagulopathy applications.

Indexed as

catsCoaguChek® XScoagulation testingpoint-of-care testingprothrombin time

Identifiers

PMID33363352
PMCPMC7750227
OpenAlexW3109496319

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.