Evidence map›Paper›PMID 33362200›Full record

ArticlePloS one2020

Particle swarm optimization algorithm-based PI inverter controller for a grid-connected PV system.

M F Roslan, Ali Q Al-Shetwi, M A Hannan, P J Ker, A W M Zuhdi

Erratum issuedAbstract read
In one paragraph

Article in PloS one, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

5 authors.

M F RoslanDepartment of Electrical Power Engineering, Universiti Tenaga Nasional, Kajang, Selangor, Malaysia.ORCID 0000-0003-0984-4210
Ali Q Al-ShetwiInstitute of Sustainable Energy, Universiti Tenaga Nasional, Kajang, Selangor, Malaysia.ORCID 0000-0002-6581-9629
M A HannanDepartment of Electrical Power Engineering, Universiti Tenaga Nasional, Kajang, Selangor, Malaysia.ORCID 0000-0001-8367-4112
P J KerInstitute of Sustainable Energy, Universiti Tenaga Nasional, Kajang, Selangor, Malaysia.
A W M ZuhdiInstitute of Sustainable Energy, Universiti Tenaga Nasional, Kajang, Selangor, Malaysia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The lack of control in voltage overshoot, transient response, and steady state error are major issues that are frequently encountered in a grid-connected photovoltaic (PV) system, resulting in poor power quality performance and damages to the overall power system. This paper presents the performance of a control strategy for an inverter in a three-phase grid-connected PV system. The system consists of a PV panel, a boost converter, a DC link, an inverter, and a resistor-inductor (RL) filter and is connected to the utility grid through a voltage source inverter. The main objective of the proposed strategy is to improve the power quality performance of the three-phase grid-connected inverter system by optimising the proportional-integral (PI) controller. Such a strategy aims to reduce the DC link input voltage fluctuation, decrease the harmonics, and stabilise the output current, voltage, frequency, and power flow. The particle swarm optimisation (PSO) technique was implemented to tune the PI controller parameters by minimising the error of the voltage regulator and current controller schemes in the inverter system. The system model and control strategies were implemented using MATLAB/Simulink environment (Version 2020A) Simscape-Power system toolbox. Results show that the proposed strategy outperformed other reported research works with total harmonic distortion (THD) at a grid voltage and current of 0.29% and 2.72%, respectively, and a transient response time of 0.1853s. Compared to conventional systems, the PI controller with PSO-based optimization provides less voltage overshoot by 11.1% while reducing the time to reach equilibrium state by 32.6%. The consideration of additional input parameters and the optimization of input parameters were identified to be the two main factors that contribute to the significant improvements in power quality control. Therefore, the proposed strategy effectively enhances the power quality of the utility grid, and such an enhancement contributes to the efficient and smooth integration of the PV system.

Indexed as

AlgorithmsElectric Power SuppliesElectricityEquipment DesignRenewable Energy

Identifiers

PMID33362200
PMCPMC7757891

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.