Evidence map›Paper›PMID 33353079›Full record

ArticleSensors (Basel, Switzerland)2020

Research on High-Resolution Miniaturized MEMS Accelerometer Interface ASIC.

Xiangyu Li, Yangong Zheng, Xiangyan Kong, Yupeng Liu, Danling Tang

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Xiangyu LiFaculty of Electrical Engineering and Computer Science, Ningbo University, Ningbo 315211, China.ORCID 0000-0001-5538-7829
Yangong ZhengFaculty of Electrical Engineering and Computer Science, Ningbo University, Ningbo 315211, China.ORCID 0000-0002-5034-9126
Xiangyan KongFaculty of Electrical Engineering and Computer Science, Ningbo University, Ningbo 315211, China.
Yupeng LiuSouthern Marine Science and Engineering Guangdong Laboratory, Guangdong Key Laboratory of Ocean Remote Sensing (LORS), South China Sea Institute of Oceanology, Chinese Academy of Sciences, Guangzhou 510301, China.
Danling TangSouthern Marine Science and Engineering Guangdong Laboratory, Guangdong Key Laboratory of Ocean Remote Sensing (LORS), South China Sea Institute of Oceanology, Chinese Academy of Sciences, Guangzhou 510301, China.

Funding

Guangdong Key Laboratory of Ocean Remote Sensing(South China Sea Institute of Oceanology Chinese Academy of Sciences) 2017B030301005-LORS2003National Natural Science Foundation of China 62001257 and 62071265Natural Science Foundation of Ningbo 2019A610070Natural Science Foundation of Zhejiang Province LQ20F010004the Foundation of Guangdong Science and Technology Department 2019BT02H594
6 · The paper itself

Abstract

High-precision microelectromechanical system (MEMS) accelerometers have wide application in the military and civil fields. The closed-loop microaccelerometer interface circuit with switched capacitor topology has a high signal-to-noise ratio, wide bandwidth, good linearity, and easy implementation in complementary metal oxide semiconductor (CMOS) process. Aiming at the urgent need for high-precision MEMS accelerometers in geophones, we carried out relevant research on high-performance closed-loop application specific integrated circuit (ASIC) chips. According to the characteristics of the performance parameters and output signal of MEMS accelerometers used in geophones, a high-precision closed-loop interface ASIC chip based on electrostatic time-multiplexing feedback technology and proportion integration differentiation (PID) feedback control technology was designed and implemented. The interface circuit consisted of a low-noise charge-sensitive amplifier (CSA), a sampling and holding circuit, and a PID feedback circuit. We analyzed and optimized the noise characteristics of the interface circuit and used a capacitance compensation array method to eliminate misalignment of the sensitive element. The correlated double sampling (CDS) technology was used to eliminate low-frequency noise and offset of the interface circuit. The layout design and engineering batch chip were fabricated by a standard 0.35 μm CMOS process. The active area of the chip was 3.2 mm × 3 mm. We tested the performance of the accelerometer system with the following conditions: power dissipation of 7.7 mW with a 5 V power supply and noise density less than 0.5 μg/Hz

Indexed as

AccelerometryMicro-Electrical-Mechanical SystemsAmplifiers, ElectronicSemiconductorsSignal-To-Noise Ratioclosed-loopinterface circuitMEMS accelerometersPID feedback

Identifiers

PMID33353079
PMCPMC7765797

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.