ArticleSensors (Basel, Switzerland)2020
Optimization and Fabrication of an MOEMS Gyroscope Based on a WGM Resonator.
Article in Sensors (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
In this paper, the characterization of a whispering gallery mode (WGM) resonator applied in a novel micro-opto-electro-mechanical system (MOEMS) gyroscope was investigated. The WGM optical transmission coupling model was analyzed and compared by adjusting key parameters, such as the cavity radius, the waveguide width, and the gap between them for silicon and silicon nitride materials in simulations, which will greatly affect the quality factor (Q) of the WGM resonator. Furthermore, the structural parameters of the disk resonant gyroscope were also optimized. Then, the fabrication process was optimized to overcome the difficulties in the realization of micro-optical devices. Finally, a gyroscope prototype with the integrated WGM resonator was verified experimentally. The scale factor and bias instability performance of the MOEMS gyroscope was 2.63 mv/°/s and 4.0339°/h, respectively.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.