Evidence map›Paper›PMID 33352691›Full record

ArticleMaterials (Basel, Switzerland)2020

Biomechanical Design and Prototyping of a Powered Ankle-Foot Prosthesis.

Stefano Alleva, Michele Gabrio Antonelli, Pierluigi Beomonte Zobel, Francesco Durante

Open access · goldAbstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.0field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 16 citations in OpenAlex.

  1. Intelligent ankle-foot prosthesis based on human structure and motion bionics.Journal of neuroengineering and rehabilitation · 2024
    Article
  2. Novel Load Systems forMaterials (Basel, Switzerland) · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Stefano AllevaDipartimento di Ingegneria Industriale e dell'Informazione e di Economia-DIIIE, Università dell'Aquila, Monteluco di Roio, 67100 L'Aquila, Italy.
Michele Gabrio AntonelliDipartimento di Ingegneria Industriale e dell'Informazione e di Economia-DIIIE, Università dell'Aquila, Monteluco di Roio, 67100 L'Aquila, Italy.ORCID 0000-0001-8437-9131
Pierluigi Beomonte ZobelDipartimento di Ingegneria Industriale e dell'Informazione e di Economia-DIIIE, Università dell'Aquila, Monteluco di Roio, 67100 L'Aquila, Italy.ORCID 0000-0003-2245-1120
Francesco DuranteDipartimento di Ingegneria Industriale e dell'Informazione e di Economia-DIIIE, Università dell'Aquila, Monteluco di Roio, 67100 L'Aquila, Italy.ORCID 0000-0001-8114-7693
University of L'Aquila · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Powered ankle-foot prostheses for walking often have limitations in the range of motion and in push-off power, if compared to a lower limb of a healthy person. A new design of a powered ankle-foot prosthesis is proposed to obtain a wide range of motion and an adequate power for a push-off step. The design methodology for this prosthesis has three points. In the first one, a dimensionless kinematic model of the lower limb in the sagittal plane is built, through an experimental campaign with healthy subjects, to calculate the angles of lower limb during the gait. In the second point a multibody inverse dynamic model of the lower limb is constructed to calculate the foot-ground contact force, its point of application and the ankle torque too, entering as input data the calculated angles of the lower limb in the previous point. The third point requires, as input of the inverse dynamic model, the first dimensioning data of the ankle-foot prosthesis to obtain the load acting on the components of the prosthesis and the angle torque of the actuator during the gait cycle. Finally, an iteration cycle begins with the inverse dynamic model modifying the ankle torque and angle until these quantities during the gait are as close as possible to the physiological quantities. After the mechanical design and the construction of the prototype of the prosthesis, an experimental methodology was used for preliminary validation of the design. The preliminary tests in the laboratory on the prototype alone show that the range of motion of the ankle angle during the gait is close to a healthy person's: 27.6° vs. 29°. The pushing force of the distal area of the prototype is 1.000 N, instead of 1.600 N, because a budget reduction forced us to choose components for the prototype with lower performance.

Indexed as

ankle-foot prosthesisbiomechanical designexperimental validation

Identifiers

PMID33352691
PMCPMC7766738
OpenAlexW3114546223

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.