The cuffless SOMNOtouch NIBP device shows poor agreement with a validated oscillometric device during 24-h ambulatory blood pressure monitoring.
Article in Journal of clinical hypertension (Greenwich, Conn.), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed, 1 synthesis or guideline pooled it, 36 citations in OpenAlex.
- Wearable Blood Pressure Monitoring Devices: Understanding Heterogeneity in Design and Evaluation.IEEE transactions on bio-medical engineering · 2024Pooled it
- Continuous blood pressure monitoring via hemodynamic parameter and pulse transit time derived from capacitive sensing pads.Physiological measurement · 2026Article
- MARU-MTL: A Mamba-Enhanced Multi-Task Learning Framework for Continuous Blood Pressure Estimation Using Radar Pulse Waves.Bioengineering (Basel, Switzerland) · 2026Article
- Comparative assessment of pulse transit time-derived blood pressure and ambulatory blood pressure monitoring in patients with obstructive sleep apnea.Sleep & breathing = Schlaf & Atmung · 2026Article
- Wearable, cuffless, and portable devices for blood pressure monitoring (2015-2025): a scoping review of technologies, calibration, clinical validation, and regulatory frameworks.Frontiers in digital health · 2026Article
- Comparing the accuracy of continuous blood pressure monitoring using wearable cuffless devices with conventional 24-hour ambulatory blood pressure monitoring: A systematic review and meta-analysis.American journal of preventive cardiology · 2025Article
- UTransBPNet for cuffless and calibration-free blood pressure estimation under dynamic conditions.Scientific reports · 2025Article
- Nanocomposite Multimodal Sensor Array Integrated with Auxetic Structure for an Intelligent Biometrics System.Small (Weinheim an der Bergstrasse, Germany) · 2024Article
- Effect of Cuff Inflation on Blood Pressure, Arousals, Sleep Efficiency, and Desaturations: Sub-Analysis of the VAST Pilot Study.Diagnostics (Basel, Switzerland) · 2023Article
- Blood pressure estimation and its recalibration assessment using wrist cuff blood pressure monitor.Biomedical engineering letters · 2023Article
- Influence of Photoplethysmogram Signal Quality on Pulse Arrival Time during Polysomnography.Sensors (Basel, Switzerland) · 2023Article
- Patent landscape review of non-invasive medical sensors for continuous monitoring of blood pressure and their validation in critical care practice.Frontiers in medicine · 2023Review
- The pre-ejection period is a highly stress dependent parameter of paramount importance for pulse-wave-velocity based applications.Frontiers in cardiovascular medicine · 2023Article
- Cuff-less blood pressure measurement with pulse transit time: The importance of rigorous assessment.Journal of clinical hypertension (Greenwich, Conn.) · 2021Article
Corrections and comments
- Commented on by
Authors and funding
4 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Repeated cuff-based blood pressure (BP) measurements may cause discomfort resulting in stress and erroneous recording values. SOMNOtouch NIBP is an alternative cuff-less BP measurement device that calculates changes in BP based on changes in pulse transit time (PTT) and a software algorithm. The device is calibrated with a single upper arm cuff-based BP measurement. We tested the device against a validated 24-h ambulatory BP monitoring (ABPM) device using both the previous (SomBP1) and the current software algorithm (SomBP2). In this study, 51 patients (mean age ± SD 61.5 ± 13.0 years) with essential hypertension underwent simultaneous 24-h ABPM with the SOMNOtouch NIBP on the left arm and a standard cuff-based oscillometric device on the right arm (OscBP). We found that mean daytime systolic BP (SBP) with OscBP was 140.8 ± 19.7 compared to 148.0 ± 25.2 (P = .008) and 146.9 ± 26.0 mmHg (P = .034) for SomBP1 and SomBP2, respectively. Nighttime SBP with OscBP was 129.5 ± 21.1 compared with 146.1 ± 25.8 (P < .0001) and 141.1 ± 27.4 mmHg (P = .001) for SomBP1 and SomBP2, respectively. Ninety-five% limits of agreement between OscBP and SomBP1 were ± 36.6 mmHg for daytime and ± 42.6 mmHg for nighttime SBP, respectively. Agreements were not improved with SomBP2. For SBP, a nocturnal dipping pattern was found in 33% of the study patients when measured with OscBP but only in 2% and 20% with SomBP1 and -2, respectively. This study demonstrates that BP values obtained with the cuff-less PTT-based SOMNOtouch device should be interpreted with caution as these may differ substantially from what would be obtained from a validated cuff-based BP device.