Evidence map›Paper›PMID 33347403›Full record

ArticleIEEE transactions on bio-medical engineering2021

Combined Ultrasound and Photoacoustic Image Guidance of Spinal Pedicle Cannulation Demonstrated With Intact ex vivo Specimens.

Eduardo A Gonzalez, Amit Jain, Muyinatu A Lediju Bell

Open access · hybridAbstract read
In one paragraph

Article in IEEE transactions on bio-medical engineering, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 23 papers.

0numbers the graph read from it
0cells of the map it votes in
23citing papers in PubMed
2.6field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

23 citing papers in PubMed, 46 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Review
  5. Article
  6. Deep Learning to Localize Photoacoustic Sources in Three Dimensions: Theory and Implementation.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2025
    Article
  7. Article
  8. Article
  9. Review
  10. Review
  11. Article
  12. Robot-assisted ultrasound reconstruction for spine surgery: from bench-top to pre-clinical study.International journal of computer assisted radiology and surgery · 2023
    Article
  13. Article
  14. Review
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Eduardo A Gonzalez
Amit Jain
Muyinatu A Lediju Bell
Johns Hopkins University · US

Funding

Coherence-Based Photoacoustic Image Guidance of Transsphenoidal SurgeriesR00EB018994 · NIBIB · JOHNS HOPKINS UNIVERSITY · PI BELL, MUYINATU A. LEDIJU · 2017 to 2019
$726k
NIBIB NIH HHS R00 EB018994
6 · The paper itself

Abstract

objectiveSpinal fusion surgeries require accurate placement of pedicle screws in anatomic corridors without breaching bone boundaries. We are developing a combined ultrasound and photoacoustic image guidance system to avoid pedicle screw misplacement and accidental bone breaches, which can lead to nerve damage.

methodsPedicle cannulation was performed on a human cadaver, with co-registered photoacoustic and ultrasound images acquired at various time points during the procedure. Bony landmarks obtained from coherence-based ultrasound images of lumbar vertebrae were registered to post-operative CT images. Registration methods were additionally tested on an ex vivo caprine vertebra.

resultsLocally weighted short-lag spatial coherence (LW-SLSC) ultrasound imaging enhanced the visualization of bony structures with generalized contrast-to-noise ratios (gCNRs) of 0.99 and 0.98-1.00 in the caprine and human vertebrae, respectively. Short-lag spatial coherence (SLSC) and amplitude-based delay-and-sum (DAS) ultrasound imaging generally produced lower gCNRs of 0.98 and 0.84, respectively, in the caprine vertebra and 0.84-0.93 and 0.34-0.99, respectively, in the human vertebrae. The mean ± standard deviation of the area of -6 dB contours created from DAS photoacoustic images acquired with an optical fiber inserted in prepared pedicle holes (i.e., fiber surrounded by cancellous bone) and holes created after intentional breaches (i.e., fiber exposed to cortical bone) was 10.06 ±5.22 mm

conclusionsCoherence-based LW-SLSC and SLSC beamforming improved visualization of bony anatomical landmarks for ultrasound-to-CT registration, while amplitude-based DAS beamforming successfully distinguished photoacoustic signals within the pedicle from less desirable signals characteristic of impending bone breaches. SIGNIFICANCE: These results are promising to improve visual registration of ultrasound and photoacoustic images with CT images, as well as to assist surgeons with identifying and avoiding impending bone breaches during pedicle cannulation in spinal fusion surgeries.

Indexed as

Spinal FusionSurgery, Computer-AssistedAnimalsCatheterizationGoatsHumansLumbar VertebraeUltrasonography

Identifiers

PMID33347403
PMCPMC8345233
OpenAlexW3114479637

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.