ArticleJMIR mHealth and uHealth2020
Accuracy of Monocular Two-Dimensional Pose Estimation Compared With a Reference Standard for Kinematic Multiview Analysis: Validation Study.
Article in JMIR mHealth and uHealth, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed.
- Evaluation of Smartphone Camera Positioning on Artificial Intelligence Pose Estimation Accuracy for Exercise Detection: Observational Study.JMIR mHealth and uHealth · 2026Observational
- Validating Single-Camera Pose Estimation Against Multi-Camera Motion Capture for Accessible Biomechanical Assessment.IEEE access : practical innovations, open solutions · 2026Article
- Gait Analysis Using Walking-Generated Acceleration Obtained from Two Sensors Attached to the Lower Legs.Sensors (Basel, Switzerland) · 2025Article
- The Future of Clinical Active Shoulder Range of Motion Assessment, Best Practice, and Its Challenges: Narrative Review.Sensors (Basel, Switzerland) · 2025Review
- Feasibility of a kinect-based system in assessing physical function of the elderly for home-based care.BMC geriatrics · 2023Article
- Evaluation of Various State of the Art Head Pose Estimation Algorithms for Clinical Scenarios.Sensors (Basel, Switzerland) · 2022Article
- App-Based Evaluation of Older People's Fall Risk Using the mHealth App Lindera Mobility Analysis: Exploratory Study.JMIR aging · 2022Article
- Frailty Level Classification of the Community Elderly Using Microsoft Kinect-Based Skeleton Pose: A Machine Learning Approach.Sensors (Basel, Switzerland) · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundExpensive optoelectronic systems, considered the gold standard, require a laboratory environment and the attachment of markers, and they are therefore rarely used in everyday clinical practice. Two-dimensional (2D) human pose estimations for clinical purposes allow kinematic analyses to be carried out via a camera-based smartphone app. Since clinical specialists highly depend on the validity of information, there is a need to evaluate the accuracy of 2D pose estimation apps.
objectiveThe aim of the study was to investigate the accuracy of the 2D pose estimation of a mobility analysis app (Lindera-v2), using the PanopticStudio Toolbox data set as a reference standard. The study aimed to assess the differences in joint angles obtained by 2D video information generated with the Lindera-v2 algorithm and the reference standard. The results can provide an important assessment of the adequacy of the app for clinical use.
methodsTo evaluate the accuracy of the Lindera-v2 algorithm, 10 video sequences were analyzed. Accuracy was evaluated by assessing a total of 30,000 data pairs for each joint (10 joints in total), comparing the angle data obtained from the Lindera-v2 algorithm with those of the reference standard. The mean differences of the angles were calculated for each joint, and a comparison was made between the estimated values and the reference standard values. Furthermore, the mean absolute error (MAE), root mean square error, and symmetric mean absolute percentage error of the 2D angles were calculated. Agreement between the 2 measurement methods was calculated using the intraclass correlation coefficient (ICC[A,2]). A cross-correlation was calculated for the time series to verify whether there was a temporal shift in the data.
resultsThe mean difference of the Lindera-v2 data in the right hip was the closest to the reference standard, with a mean value difference of -0.05° (SD 6.06°). The greatest difference in comparison with the baseline was found in the neck, with a measurement of -3.07° (SD 6.43°). The MAE of the angle measurement closest to the baseline was observed in the pelvis (1.40°, SD 1.48°). In contrast, the largest MAE was observed in the right shoulder (6.48°, SD 8.43°). The medians of all acquired joints ranged in difference from 0.19° to 3.17° compared with the reference standard. The ICC values ranged from 0.951 (95% CI 0.914-0.969) in the neck to 0.997 (95% CI 0.997-0.997) in the left elbow joint. The cross-correlation showed that the Lindera-v2 algorithm had no temporal lag.
conclusionsThe results of the study indicate that a 2D pose estimation by means of a smartphone app can have excellent agreement compared with a validated reference standard. An assessment of kinematic variables can be performed with the analyzed algorithm, showing only minimal deviations compared with data from a massive multiview system.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.