Evidence map›Paper›PMID 33342042›Full record

ArticleJournal of applied clinical medical physics2021

Risk of target coverage loss for stereotactic body radiotherapy treatment of synchronous lung lesions via single-isocenter volumetric modulated arc therapy.

Lana C Critchfield, Mark E Bernard, Marcus E Randall, Ronald C McGarry, Damodar Pokhrel

Open access · goldAbstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.0field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Lana C CritchfieldMedical Physics Graduate Program, Department of Radiation Medicine, University Kentucky, Lexington, KY, USA.
Mark E BernardMedical Physics Graduate Program, Department of Radiation Medicine, University Kentucky, Lexington, KY, USA.
Marcus E RandallMedical Physics Graduate Program, Department of Radiation Medicine, University Kentucky, Lexington, KY, USA.
Ronald C McGarryMedical Physics Graduate Program, Department of Radiation Medicine, University Kentucky, Lexington, KY, USA.
Damodar PokhrelMedical Physics Graduate Program, Department of Radiation Medicine, University Kentucky, Lexington, KY, USA.
University of Kentucky · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Treating multiple lung lesions synchronously via single-isocenter volumetric modulated arc therapy (VMAT) stereotactic body radiation therapy (SBRT) improves treatment efficiency and patient compliance. However, aligning multiple lung tumors accurately on single pretreatment cone beam CTs (CBCTs) can be problematic. Tumors misaligned could lead to target coverage loss. To quantify this potential target coverage loss due to small, clinically realistic setup errors, a novel simulation method was developed. This method was used on 26 previously treated patients with two metastatic lung lesions. Patients were treated with 4D CT-based, highly conformal noncoplanar VMAT plans (clinical VMAT) with 6MV-flattening filter free (FFF) beam using AcurosXB dose calculation algorithm with heterogeneity corrections. A single isocenter was placed approximately between the lesions to improve patient convenience and clinic workflow. Average isocenter to tumor distance was 5.9 cm. Prescription dose was 54 Gy/50 Gy in 3/5 fractions. For comparison, a plan summation (simulated VMAT) was executed utilizing randomly simulated, clinically relevant setup errors, obtained from pretreatment setup, per treatment fraction, in Eclipse treatment planning system for each of the six degrees of freedom within ± 5.0 mm and ± 2°. Simulations yielded average deviations of 27.4% (up to 72% loss) (P < 0.001) from planned target coverage when treating multiple lung lesions using a single-isocenter plan. The largest deviations from planned coverage and desired biological effective dose (BED10, with α/β = 10 Gy) were seen for the smallest targets (<10 cc), some of which received < 100 Gy BED10. Patient misalignment resulted in substantial decrease in conformity and increase in the gradient index, violating major characteristics of SBRT. Statistically insignificant differences were seen for normal tissue dose. Although, clinical follow-up of these patients is ongoing, the authors recommend an alternative treatment planning strategy to minimize the probability of a geometric miss when treating small lung lesions synchronously with single-isocenter VMAT SBRT plans.

Indexed as

RadiosurgeryRadiotherapy, Intensity-ModulatedHumansLungOrgans at RiskRadiotherapy DosageRadiotherapy Planning, Computer-AssistedBED10coverage losslung SBRTsetup errorssingle-Isocenter VMATsynchronous

Identifiers

PMID33342042
PMCPMC7856510
OpenAlexW3116769225

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.