ArticleJournal of applied clinical medical physics2021
Feasibility of automated planning for whole-brain radiation therapy using deep learning.
Article in Journal of applied clinical medical physics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed, 1 synthesis or guideline pooled it, 12 citations in OpenAlex.
- Performance of artificial intelligence for brain tumor segmentation, treatment planning, and outcome prediction: a comprehensive systematic review and meta-analysis.Journal of neuro-oncology · 2025Pooled it
- Human-like AI-based auto-field-in-field whole-brain radiotherapy treatment planning with conversation large language model feedback.Journal of applied clinical medical physics · 2026Article
- Desargues cloud TPS: a cloud-based automatic radiation treatment planning system for IMRT.Biomedical engineering online · 2026Article
- Article
- Automated treatment planning for brain and spinal metastases.Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology · 2026Article
- Deep-neural network approaches for predicting 3D dose distribution in intensity-modulated radiotherapy of the brain tumors.Journal of applied clinical medical physics · 2024Article
- Automated field-in-field whole brain radiotherapy planning.Journal of applied clinical medical physics · 2023Article
- A Survey on Deep Learning for Precision Oncology.Diagnostics (Basel, Switzerland) · 2022Review
- Assessment of efficacy in automated plan generation for Varian Ethos intelligent optimization engine.Journal of applied clinical medical physics · 2022Article
- Semiautomatic Treatment Planning for the Field-in-field Technique in Whole Brain Irradiation.Juntendo Iji zasshi = Juntendo medical journal · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 1 institution in 1 country.
Funding
Abstract
purposeThe purpose of this study was to develop automated planning for whole-brain radiation therapy (WBRT) using a U-net-based deep-learning model for predicting the multileaf collimator (MLC) shape bypassing the contouring processes.
methodsA dataset of 55 cases, including 40 training sets, five validation sets, and 10 test sets, was used to predict the static MLC shape. The digitally reconstructed radiograph (DRR) reconstructed from planning CT images as an input layer and the MLC shape as an output layer are connected one-to-one via the U-net modeling. The Dice similarity coefficient (DSC) was used as the loss function in the training and ninefold cross-validation. Dose-volume-histogram (DVH) curves were constructed for assessing the automatic MLC shaping performance. Deep-learning (DL) and manually optimized (MO) approaches were compared based on the DVH curves and dose distributions.
resultsThe ninefold cross-validation ensemble test results were consistent with DSC values of 94.6 ± 0.4 and 94.7 ± 0.9 in training and validation learnings, respectively. The dose coverages of 95% target volume were (98.0 ± 0.7)% and (98.3 ± 0.8)%, and the maximum doses for the lens as critical organ-at-risk were 2.9 Gy and 3.9 Gy for DL and MO, respectively. The DL technique shows the consistent results in terms of the DVH parameter except for MLC shaping prediction for dose saving of small organs such as lens.
conclusionsComparable with the MO plan result, the WBRT plan quality obtained using the DL approach is clinically acceptable. Moreover, the DL approach enables WBRT auto-planning without the time-consuming manual MLC shaping and target contouring.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.