Evidence map›Paper›PMID 33334076›Full record

ArticleMicromachines2020

Enhancement of Fluid Mixing with U-Shaped Channels on a Rotating Disc.

Chi-Wei Hsu, Po-Tin Shih, Jerry M Chen

Abstract read
In one paragraph

Article in Micromachines, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Developing Micro/Nanostructured Fluidic Mixing Technology for Biomedical Applications.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026
    Review
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Chi-Wei HsuDepartment of Mechanical Engineering, National Chung Hsing University, Taichung 402, Taiwan.
Po-Tin ShihDepartment of Mechanical Engineering, National Chung Hsing University, Taichung 402, Taiwan.
Jerry M ChenDepartment of Mechanical Engineering, National Chung Hsing University, Taichung 402, Taiwan.ORCID 0000-0003-4245-9066

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In this study, centrifugal microfluidics with a simple geometry of U-shaped structure was designed, fabricated and analyzed to attain rapid and efficient fluid mixing. Visualization experiments together with numerical simulations were carried out to investigate the mixing behavior for the microfluidics with single, double and triple U-shaped structures, where each of the U-structures consisted of four consecutive 90° bends. It is found that the U-shaped structure markedly enhances mixing by transverse secondary flow that is originated from the Coriolis-induced vortices and further intensified by the Dean force generated as the stream turns along the 90° bends. The secondary flow becomes stronger with increasing rotational speed and with more U-shaped structures, hence higher mixing performance. The mixing efficiency measured for the three types of mixers shows a sharp increase with increasing rotational speed in the lower range. As the rotational speed further increases, nearly complete mixing can be achieved at 600 rpm for the triple-U mixer and at 720 rpm for the double-U mixer, while a maximum efficiency level of 83-86% is reached for the single-U mixer. The simulation results that reveal detailed characteristics of the flow and concentration fields are in good agreement with the experiments.

Indexed as

centrifugal microfluidicsCoriolis forceflow visualizationmicromixermixing efficiencyU-shaped channel

Identifiers

PMID33334076
PMCPMC7765561

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.