Evidence map›Paper›PMID 33329769›Full record

ArticleAnesthesia and pain medicine2019

Accuracy assessment of a PION TCI pump based on international standards.

Il Doh, Seok Hwan Lee, Yong-Hun Lee, Bokyoung Jeon, Byung-Moon Choi, Gyu-Jeong Noh

Abstract read
In one paragraph

Article in Anesthesia and pain medicine, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Il DohCenter for Medical Metrology, Korea Research Institute of Standards and Science (KRISS), Daejeon, Korea.ORCID 0000-0002-1639-7730
Seok Hwan LeeCenter for Thermometry and Fluid Flow Metrology, Korea Research Institute of Standards and Science (KRISS), Daejeon, Korea.ORCID 0000-0003-2477-365X
Yong-Hun LeeDepartment of Anesthesiology and Pain Medicine, University of Ulsan College of Medicine, Seoul, Korea.ORCID 0000-0002-6561-8851
Bokyoung JeonDepartment of Anesthesiology and Pain Medicine, University of Ulsan College of Medicine, Seoul, Korea.ORCID 0000-0002-6561-8851
Byung-Moon ChoiDepartment of Anesthesiology and Pain Medicine, University of Ulsan College of Medicine, Seoul, Korea.ORCID 0000-0002-6561-8851
Gyu-Jeong NohDepartment of Anesthesiology and Pain Medicine, University of Ulsan College of Medicine, Seoul, Korea.ORCID 0000-0002-6561-8851

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundInaccuracies associated with target-controlled infusion (TCI) delivery systems are attributable to both software and hardware issues, as well as pharmacokinetic variability. However, little is known about the inaccuracy of the syringe pump operating in TCI mode. This study aimed to evaluate the accuracy of the TCI pump based on international standards.

methodsA test apparatus for accuracy evaluation of a syringe pump (PION TCI

resultsThe representative infusion rate representing TCI mode was 31 ml/h, at which the infusion rate deviation was 4.5 ± 1.6%.

conclusionsThe inaccuracy of the syringe pump contributing to TCI system inaccuracy is insignificant.

Indexed as

AccuracyInfusionPump

Identifiers

PMID33329769
PMCPMC7713806

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.