Evidence map›Paper›PMID 33327521›Full record

ArticleSensors (Basel, Switzerland)2020

A Method for Improving the Detection Accuracy of the Spot Position of the Four-Quadrant Detector in a Free Space Optical Communication System.

Xuan Wang, Xiuqin Su, Guizhong Liu, Junfeng Han, Kaidi Wang, Wenhua Zhu

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Xuan WangXi'an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi'an 710119, China.ORCID 0000-0001-8445-1391
Xiuqin SuXi'an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi'an 710119, China.
Guizhong LiuSchool of Electronic and Information Engineering, Xi'an Jiaotong University, Xi'an 710049, China.
Junfeng HanXi'an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi'an 710119, China.
Kaidi WangXi'an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi'an 710119, China.
Wenhua ZhuXi'an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi'an 710119, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In a free space optical communication system, the beacon light will lose most of its energy after long-distance transmission, and the background light from the universe will strongly interfere with it. The four-quadrant detector (4QD) has been widely used in optical communication systems as a high-precision spot position detection sensor. However, if the light signal falling on the 4QD is too weak, the electrical signal of the output position will be very weak, and it will easily be affected by or even submerged in noise. To solve this problem, we propose a method for improving the spot position detection accuracy. First, we analyzed the solution relationship between the actual position of the spot and the output signal of the 4QD, with a Gaussian spot as the incident light model. The output current signal of the detector was then transimpedance-amplified by an analog circuit and the output voltage signal with noise was digitally filtered. An error compensation factor and the gap size of the detector were introduced into the traditional spot position detection model. High-precision spot position information for the 4QD in a complex environment was then obtained using the improved spot position detection model. Experimental results show that the maximum spot position detection error for this method was only 0.0277 mm, and the root mean square error was 0.0065 mm, when the 4QD was in a high background noise environment. The spot position detection accuracy was significantly improved compared with traditional detection algorithms. Real-time detection can therefore be achieved in practical applications.

Indexed as

Gaussian spothigh background noisequadrant detectors

Identifiers

PMID33327521
PMCPMC7765015

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.