Evidence map›Paper›PMID 33325131›Full record

ArticleThoracic cancer2021

Placement of self-expanding metallic tracheobronchial Y stent with laryngeal mask airway using conscious sedation under fluoroscopic guidance.

Barak Pertzov, Evgeni Gershman, Shimon Izhakian, Shai M Amor, Dror Rosengarten, Mordechai R Kramer

Open access · goldAbstract read
In one paragraph

Article in Thoracic cancer, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed, 1 pooled it
0.3field-weighted citation impact, top 37% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 1 synthesis or guideline pooled it, 8 citations in OpenAlex.

  1. Pooled it
  2. Review
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Barak PertzovThe Pulmonary Division, Rabin Medical Center, Petach Tikva, Israel.ORCID 0000-0002-3077-3616
Evgeni GershmanThe Pulmonary Division, Rabin Medical Center, Petach Tikva, Israel.
Shimon IzhakianThe Pulmonary Division, Rabin Medical Center, Petach Tikva, Israel.
Shai M AmorThe Pulmonary Division, Rabin Medical Center, Petach Tikva, Israel.
Dror RosengartenThe Pulmonary Division, Rabin Medical Center, Petach Tikva, Israel.
Mordechai R KramerThe Pulmonary Division, Rabin Medical Center, Petach Tikva, Israel.
Tel Aviv University · IL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundCentral airway obstruction and fistula are treated with a tracheobronchial Y stent. In the currently used self-expandable metal Y stents, the delivery system is 8 mm in diameter and requires either a 9 mm tracheal tube or rigid bronchoscope to enable airway control during insertion. In this study we present a novel technique of laryngeal mask airway (LMA) assisted Y stent insertion, enabling airway control during deployment of the Y stent.

methodsAll procedures using LMA in assisting Y stent insertions between 2014-2020 were reviewed. Data collected included demographics, clinical diagnosis and disease characteristics, indication, procedural success rates, clinical outcome and survival.

resultsA total of 10 patients with a median age of 61.5 years (range 37-73) underwent LMA assisted Y stent insertion. Indications for stent insertion were malignant disease with central airway obstruction or fistula. In all cases airway patency was achieved leading to improvement of symptoms and performance status. No procedural complications were reported. The median survival was 4.5 weeks (range: 2-26).

conclusionsLMA assisted Y stent insertion enables airway control during the procedure. In comparison to silicone Y stent insertion, the procedure is less cumbersome, shorter in duration and does not require the use of general anesthesia or rigid bronchoscopy. KEY POINTS: SIGNIFICANT FINDINGS OF THE STUDY: LMA assisted Y stent insertion enables airway control during the implantation of metallic self-expanding Y stent. The procedure does not require the use of general anesthesia or rigid bronchoscopy. WHAT THIS STUDY ADDS: In this study we present the technique and outcomes of LMA assisted Y stent insertion. This method of Y stent insertion provides an additional treatment option for patients with central airway obstruction and fistula.

Indexed as

AdultAgedAirway ObstructionFemaleFluoroscopyHumansLaryngeal MasksMaleMiddle AgedProcedural SedationStentsTreatment OutcomeCentral airwayfistulamalignantobstructionY stent

Identifiers

PMID33325131
PMCPMC7882393
OpenAlexW3113346871

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.