Evidence map›Paper›PMID 33325033›Full record

ArticleMedical physics2021

Rapid measurement of the low contrast detectability of CT scanners.

Akinyinka Omigbodun, J Y Vaishnav, Scott S Hsieh

Abstract read
In one paragraph

Article in Medical physics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. A dense search challenge phantom fabricated with pixel-based 3D printing for precise detectability assessment.Proceedings of SPIE--the International Society for Optical Engineering · 2023
    Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Akinyinka OmigbodunDepartment of Radiological Sciences, UCLA, Los Angeles, CA, 90024, USA.
J Y VaishnavCanon Medical Systems, U.S.A., Tustin, CA, 92780, USA.
Scott S HsiehDepartment of Radiological Sciences, UCLA, Los Angeles, CA, 90024, USA.

Funding

Dissemination of a Software Platform for Efficient CT Radiation Dose Optimization and Diagnostic Performance AssessmentU24EB028936 · NIBIB · MAYO CLINIC ROCHESTER · PI YU, LIFENG · 2019 to 2023
$1.6M
NIBIB NIH HHS U24 EB028936NIH HHS U24EB028936
6 · The paper itself

Abstract

purposeLow contrast detectability (LCD) is a metric of fundamental importance in computed tomography (CT) imaging. In spite of this, its measurement is challenging in the context of nonlinear data processing. We introduce a new framework for objectively characterizing LCD with a single scan of a special-purpose phantom and automated analysis software. The output of the analysis software is a "machine LCD" metric which is more representative of LCD than contrast-noise ratio (CNR). It is not intended to replace human observer or model observer studies.

methodsFollowing preliminary simulations, we fabricated a phantom containing hundreds of low-contrast beads. These beads are acrylic spheres (1.6 mm, net contrast ~10 HU) suspended and randomly dispersed in a background matrix of nylon pellets and isoattenuating saline. The task was to search for and localize the beads. A modified matched filter was used to automatically scan the reconstruction and select candidate bead localizations of varying confidence. These were compared to bead locations as determined from a high-dose reference scan to produce free-response ROC curves. We compared iterative reconstruction (IR) and filtered backpropagation (FBP) at multiple dose levels between 40 and 240 mAs. The scans at 60, 120, and 180 mAs were performed three times each to estimate uncertainty.

resultsExperimental scans demonstrated the feasibility of our technique. Our metric for machine LCD was the area under the exponential transform of the FROC curve (AUC). AUC increased monotonically from 0.21 at 40 mAs to 0.84 at 240 mAs. The sample standard deviation of AUC was approximately 0.02. This measurement uncertainty in AUC corresponded to a change in tube current of 4% to 8%. Surprisingly, we found that AUCs for IR were slightly worse than AUCs for FBP. While the phantom was sufficient for these experiments, it contained small air bubbles and alternative fabrication methods will be necessary for widespread utilization.

conclusionsIt is feasible to measure machine LCD using a search task on a phantom with hundreds of beads and to obtain tight error bars using only a single scan. Our method could facilitate routine quality assurance or possibly enable comparisons between different protocols and scanners.

Indexed as

AlgorithmsTomography Scanners, X-Ray ComputedTomography, X-Ray ComputedHumansPhantoms, ImagingRadiation DosageRadiographic Image Interpretation, Computer-Assisteddose reductionlow-contrast detectabilityquality assurance

Identifiers

PMID33325033
PMCPMC8058889

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.