Quantification and correction of the scattered X-rays from a megavoltage photon beam to a linac-mounted kilovoltage imaging subsystem.

Hiraku Iramina, Mitsuhiro Nakamura, Yuki Miyabe, Nobutaka Mukumoto, Tomohiro Ono, Hideaki Hirashima, Takashi Mizowaki

Abstract read
In one paragraph

Article in BJR open, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Megavoltage cross-scatter rejection and correction using 2D antiscatter grids in kilovoltage CBCT imaging.Proceedings of SPIE--the International Society for Optical Engineering · 2022
    Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Hiraku IraminaDepartment of Radiation Oncology and Image-applied Therapy, Kyoto University Hospital, Kyoto 606-8507, Japan.
Mitsuhiro Nakamura
Yuki MiyabeDepartment of Radiation Oncology and Image-applied Therapy, Kyoto University Hospital, Kyoto 606-8507, Japan.
Nobutaka MukumotoDepartment of Radiation Oncology and Image-applied Therapy, Kyoto University Hospital, Kyoto 606-8507, Japan.
Tomohiro OnoDepartment of Radiation Oncology and Image-applied Therapy, Kyoto University Hospital, Kyoto 606-8507, Japan.
Hideaki HirashimaDepartment of Radiation Oncology and Image-applied Therapy, Kyoto University Hospital, Kyoto 606-8507, Japan.
Takashi Mizowaki

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo quantify and correct megavoltage (MV) scattered X-rays (MV-scatter) on an image acquired using a linac-mounted kilovoltage (kV) imaging subsystem. METHODS AND MATERIALS: A linac-mounted flat-panel detector (FPD) was used to acquire an image containing MV-scatter by activating the FPD only during MV beam irradiation. 6-, 10-, and 15 MV with a flattening-filter (FF; 6X-FF, 10X-FF, 15X-FF), and 6- and 10 MV without an FF (6X-FFF, 10X-FFF) were used. The maps were acquired by changing one of the irradiation parameters while the others remained fixed. The mean pixel values of the MV-scatter were normalized to the 6X-FF reference condition (MV-scatter value). An MV-scatter database was constructed using these values. An MV-scatter correction experiment with one full arc image acquisition and two square field sizes (FSs) was conducted. Measurement- and estimation-based corrections were performed using the database. The image contrast was calculated at each angle.

resultsThe MV-scatter increased with a larger FS and dose rate. The MV-scatter value factor varied substantially depending on the FPD position or collimator rotation. The median relative error ranges of the contrast for the image without, and with the measurement- and estimation-based correction were -10.9 to -2.9, and -1.5 to 4.8 and -7.4 to 2.6, respectively, for an FS of 10.0 × 10.0 cm

conclusionsThe MV-scatter was strongly dependent on the FS, dose rate, and FPD position. The MV-scatter correction improved the image contrast. ADVANCES IN KNOWLEDGE: The MV-scatters on the TrueBeam linac kV imaging subsystem were quantified with various MV beam parameters, and strongly depended on the fieldsize, dose rate, and flat panel detector position. The MV-scatter correction using the constructed database improved the image quality.