ArticleOphthalmology. Glaucoma
Comparison of Clinical Outcomes with Open Versus Closed Conjunctiva Implantation of the XEN45 Gel Stent.
Article in Ophthalmology. Glaucoma. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 19 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
19 citing papers in PubMed, 2 syntheses or guidelines pooled it, 34 citations in OpenAlex.
- The efficacy of XEN gel stent implantation in glaucoma: a systematic review and meta-analysis.BMC ophthalmology · 2022Pooled it
- The Outcomes of XEN Gel Stent Implantation: A Systematic Review and Meta-Analysis.Frontiers in medicine · 2022Pooled it
- Update on XEN Gel Stent: A Narrative Review on Indications, Surgical Technique, and Postoperative Management.Ophthalmology and therapy · 2026Review
- Short-Term Preliminary Results of Outcomes with and without Tenonectomy During Open Conjunctival XEN45 Gel Stent Implantation.Clinical ophthalmology (Auckland, N.Z.) · 2026Article
- One-Year Outcomes of Repeat XEN Gel Stent Implantation for Prior XEN Failure: A Retrospective Study.Clinical ophthalmology (Auckland, N.Z.) · 2026Article
- Efficacy and Safety of Ab-externo Approach versus Ab-interno Approach of XEN45 Gel Stent Implantation: A Systematic Review and Meta-Analysis.Clinical ophthalmology (Auckland, N.Z.) · 2026Review
- XEN‑45 implantation for refractory secondary glaucoma.BMC ophthalmology · 2025Article
- Comparison of XEN45 Gel Stent Outcomes in Glaucoma: Ab Externo Open-Conjunctiva Approach with Ologen vs. Ab Interno Closed-Conjunctiva Approach.Journal of clinical medicine · 2025Article
- One-Year Real-World Outcomes of Ab-Externo Gel Stent Placement From the EXPAND Study.Journal of glaucoma · 2025Article
- Clinical Outcomes of XEN45 Gel Stent Implantation (Ab Externo, Open Conjunctival Approach) versus Trabeculectomy: A Real-World Study.Korean journal of ophthalmology : KJO · 2025Article
- Transconjunctival XEN45 implantation for secondary open-angle glaucoma management in a pediatric patient with WAGR syndrome.American journal of ophthalmology case reports · 2023Article
- One-Year Outcomes of Ab Externo XEN45 Gel Stent Implantation with an Open Conjunctiva Approach in Patients with Open-Angle Glaucoma.Korean journal of ophthalmology : KJO · 2023Article
- New Devices in Glaucoma.Ophthalmology and therapy · 2023Review
- Recent Advancements in Glaucoma Surgery-A Review.Bioengineering (Basel, Switzerland) · 2023Review
- XENJournal of clinical medicine · 2023Article
- Defining the role of ab externo Xen gel stent in glaucomatous eyes with prior failed surgical intervention.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2023Article
- Intraocular Pressure and Medication Changes Associated with Xen Gel Stent: A Systematic Review of the Literature.Clinical ophthalmology (Auckland, N.Z.) · 2023Review
- Comparison of surgical outcomes with and without Ologen collagen matrix augmentation during XEN gel stent implantation.BMC ophthalmology · 2022Article
- Surgical Outcome Comparison of Open ConjunctivalJournal of current glaucoma practiceArticle
Corrections and comments
- Erratum issued
Authors and funding
9 authors at 3 institutions in 1 country.
Funding
Abstract
purposeTo describe the efficacy and safety of open versus closed conjunctival implantation of the XEN45 Gel Stent (Allergan Inc).
designRetrospective, multicenter study.
participantsA total of 137 patients with glaucoma who underwent XEN45 implantation via open or closed conjunctival methods. The XEN45 was implanted as a stand-alone procedure or at the time of cataract surgery by 5 surgeons.
methodsPatient demographics, diagnoses, preoperative and postoperative clinical data, outcome measures including intraocular pressure (IOP), use of glaucoma medications, visual acuity, and complications were collected. Statistical analyses were performed with P < 0.05 as significant.
main outcome measuresFailure was defined as less than 20% reduction of IOP from medicated baseline or IOP >21 mmHg at 2 consecutive visits at postoperative month 1 and beyond, the need for subsequent operative intervention or additional glaucoma surgery, or a catastrophic event such as loss of light perception. Eyes that had not failed by these criteria and were not on glaucoma medications were considered complete successes. Eyes that had not failed but required glaucoma medications were defined as qualified successes.
resultsComplete success was achieved in 31% and 56% of the closed and open groups, respectively (P = 0.01). Qualified success was achieved in 53% and 71% of the closed and open groups, respectively (P = 0.06). At postoperative month 12, the open conjunctiva group was using fewer glaucoma medications than the closed group (0.9 vs. 1.8, respectively; P = 0.02). At postoperative month 12, the open group had a significantly greater percentage of IOP reduction compared with the closed group (43.1% vs. 24.8%, respectively; P = 0.02). Postoperative needling rates were higher in the closed group compared with the open group (36.1% vs. 11.8%, P = 0.001).
conclusionsImplantation of the XEN45 with opening of the conjunctiva is a safe and efficacious procedure to lower IOP with comparable success rate and lower needling rate compared with the closed conjunctiva technique. Prospective evaluation of the various methods for XEN45 implantation will allow for further comparison.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.