Evidence map›Paper›PMID 33317010›Full record

ArticleNanomaterials (Basel, Switzerland)2020

Sensitive and In Situ Hemoglobin Detection Based on a Graphene Oxide Functionalized Microfiber.

Fang Fang, Yanpeng Li, Liuyang Yang, Liangye Li, Zhijun Yan, Qizhen Sun

Abstract read
In one paragraph

Article in Nanomaterials (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Fang FangSchool of Optical and Electronic Information & National Engineer Laboratory for Next Generation Internal Access System & Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan 430074, China.
Yanpeng LiSchool of Optical and Electronic Information & National Engineer Laboratory for Next Generation Internal Access System & Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan 430074, China.
Liuyang YangSchool of Optical and Electronic Information & National Engineer Laboratory for Next Generation Internal Access System & Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan 430074, China.
Liangye LiSchool of Optical and Electronic Information & National Engineer Laboratory for Next Generation Internal Access System & Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan 430074, China.
Zhijun YanSchool of Optical and Electronic Information & National Engineer Laboratory for Next Generation Internal Access System & Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan 430074, China.
Qizhen SunSchool of Optical and Electronic Information & National Engineer Laboratory for Next Generation Internal Access System & Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan 430074, China.

Funding

National Science Fund for Excellent Young Scholars of China No. 61922033Wuhan Morning Light Plan of Youth Science and Technology No. 2017050304010280
6 · The paper itself

Abstract

The determination of hemoglobin (Hb) level is indispensable in the pathological study of many blood diseases. Graphene oxide (GO), with its excellent optical properties and great biocompatibility, has attracted significant attention and been widely utilized in biochemical detection. Here, we report an ultrasensitive Hb sensor based on a graphene oxide (GO)-coated microfiber. The GO was utilized as a linking layer deposited on the microfiber surface, which can provide an enhanced local evanescent light field and abundant bonding sites for Hb molecules. The optical microfiber with a compact structure and a strong evanescent light field served as the platform for biosensing. The surface morphology characterized by optical microscope, scanning electron microscope, and Raman spectroscopy offers detailed evidence for the success of GO deposition. The dynamic bonding between GO and target Hb molecules was monitored in real-time through an optical spectrum analyzer. An ultrahigh sensitivity of 6.02 nm/(mg/mL) with a detection limit of 0.17 μg/mL was achieved by tracking the resonant wavelength shift of spectra. It is important to highlight that the detection limit of GO-coated microfiber is 1-2 orders of magnitude lower than other reported fiber optic Hb sensors. Benefiting from high sensitivity, low cost, small size, and fast response, the proposed sensing microfiber coated with GO could be a competitive alternative in the diagnosis of blood diseases and a subject of further research in the medical field.

Indexed as

graphene oxidehemoglobinmicrofiber

Identifiers

PMID33317010
PMCPMC7763212

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.