Evidence map›Paper›PMID 33315663›Full record

ArticleASAIO journal (American Society for Artificial Internal Organs : 1992)2021

Design and Computational Evaluation of a Pediatric MagLev Rotary Blood Pump.

Landon H Tompkins, Barry N Gellman, Gino F Morello, Steven R Prina, Thomas J Roussel, Jonathan A Kopechek, Priscilla C Petit, Mark S Slaughter, Steven C Koenig, Kurt A Dasse

Open access · greenAbstract read
In one paragraph

Article in ASAIO journal (American Society for Artificial Internal Organs : 1992), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed, 1 pooled it
0.6field-weighted citation impact, top 35% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 1 synthesis or guideline pooled it, 12 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Hemodynamic evaluation andAnnals of translational medicine · 2021
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 1 institution in 1 country.

Landon H TompkinsFrom the Department of Bioengineering, University of Louisville, Louisville, Kentucky.ORCID 0000-0002-6832-2167
Barry N GellmanInspired Therapeutics LLC, Merritt Island, Florida.
Gino F MorelloVeritium Research LLC, Fort Lee, New Jersey.
Steven R PrinaBLDC Designs LLC, Rocklin, California.
Thomas J RousselFrom the Department of Bioengineering, University of Louisville, Louisville, Kentucky.ORCID 0000-0002-8430-3679
Jonathan A KopechekFrom the Department of Bioengineering, University of Louisville, Louisville, Kentucky.ORCID 0000-0001-7041-0767
Priscilla C PetitInspired Therapeutics LLC, Merritt Island, Florida.
Mark S SlaughterDepartment of Cardiovascular and Thoracic Surgery, University of Louisville, Louisville, Kentucky.
Steven C KoenigFrom the Department of Bioengineering, University of Louisville, Louisville, Kentucky.
Kurt A DasseFrom the Department of Bioengineering, University of Louisville, Louisville, Kentucky.ORCID 0000-0002-8672-4450
University of Louisville · US

Funding

Development of the Inspired Therapeutics NeoMate Mechanical Circulatory Support System for Neonates and InfantsR44HL144214 · NHLBI · INSPIRED THERAPEUTICS, LLC · PI TAMEZ, DANIEL · 2022 to 2025
$6.1M
DEVELOPMENT OF A PEDIATRIC CARDIAC AND RESPIRATORY ASSIST SYSTEMR43HL144214 · NHLBI · INSPIRED THERAPEUTICS, LLC · PI DASSE, KURT A · 2018 to 2018
$416k
NHLBI NIH HHS R43 HL144214NHLBI NIH HHS R44 HL144214
6 · The paper itself

Abstract

Pediatric heart failure (HF) patients have been a historically underserved population for mechanical circulatory support (MCS) therapy. To address this clinical need, we are developing a low cost, universal magnetically levitated extracorporeal system with interchangeable pump heads for pediatric support. Two impeller and pump designs (pump V1 and V2) for the pediatric pump were developed using dimensional analysis techniques and classic pump theory based on defined performance criteria (generated flow, pressure, and impeller diameter). The designs were virtually constructed using computer-aided design (CAD) software and 3D flow and pressure features were analyzed using computational fluid dynamics (CFD) analysis. Simulated pump designs (V1, V2) were operated at higher rotational speeds (~5,000 revolutions per minute [RPM]) than initially estimated (4,255 RPM) to achieve the desired operational point (3.5 L/min flow at 150 mm Hg). Pump V2 outperformed V1 by generating approximately 30% higher pressures at all simulated rotational speeds and at 5% lower priming volume. Simulated hydrodynamic performance (achieved flow and pressure, hydraulic efficiency) of our pediatric pump design, featuring reduced impeller size and priming volume, compares favorably to current commercially available MCS devices.

Indexed as

Heart-Assist DevicesHeart FailureChildEquipment DesignHumansHydrodynamicsProsthesis Design

Identifiers

PMID33315663
PMCPMC8187468
OpenAlexW3111153552

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.