ArticleJournal of clinical laboratory analysis2021
Sigma metrics application for validated and non-validated detecting systems performance assessment.
Article in Journal of clinical laboratory analysis, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 0 citations in OpenAlex.
- Sigma metrics application for validated and non-validated detecting systems performance assessment.Journal of clinical laboratory analysis · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundSigma metrics provide an objective and quantitative methodology for analytical quality evaluation of clinical laboratory. This study investigated the testing performance of validated systems and non-validated systems based on sigma metrics, and explored the major parameters affecting the system performance.
methodsSigma metrics were evaluated by six biochemistry assays based on Beckman and Mindray validated and non-validated systems through crossing the reagents and analyzers. Imprecision and bias were assessed for all assays based on trueness programs organized by National Centre for Clinical Laboratory. Total error allowance obtained from the Chinese Ministry of Health Clinical Laboratory Centre Industry Standard (WS/T403-2012).
resultsThe imprecision for all systems meets the quality specifications except TP assay (2.19%) detected by Mindray non-validated system, and the bias for four assays measured by non-validated systems cannot fulfill the criterion, including lactate dehydrogenase (LDH), total protein (TP), triglycerides (TG), and glucose (GLU). Higher biases were detected in six assays at different levels among non-validated and validated systems. Systems performed poorly or unacceptably for TP assay with sigma metrics lower than 3 except Mindray non-validated system. The sigma metrics for other assays with four systems were greater than 3 except the LDH evaluated on Mindray non-validated systems.
conclusionNon-validated systems may introduce performance uncertainty compared with validated systems based on sigma metrics evaluation, and lower bias was provided by validated systems. The performance of non-validated systems should be evaluated thoroughly in the clinical laboratory before they were adopted for routine use.
Indexed as