In vitro investigation of the Flusso™ Bypass adapter efficiency upon ventilator circuit disconnect in a clinical simulated environment.

Rym Mehri, Abubakar Alatrash, Nick Ogrodnik, Edgar A Matida, Frank Fiorenza

Abstract read
In one paragraph

Article in Canadian journal of respiratory therapy : CJRT = Revue canadienne de la therapie respiratoire : RCTR, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Rym MehriDepartment of Mechanical & Aerospace Engineering, Carleton University, Ottawa, ON, Canada.
Abubakar AlatrashDepartment of Mechanical & Aerospace Engineering, Carleton University, Ottawa, ON, Canada.
Nick OgrodnikDepartment of Mechanical & Aerospace Engineering, Carleton University, Ottawa, ON, Canada.
Edgar A MatidaDepartment of Mechanical & Aerospace Engineering, Carleton University, Ottawa, ON, Canada.
Frank FiorenzaProduct Development, McArthur Medical Sales Inc., Rockton, ON, Canada.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

rationaleMechanically ventilated patients must be disconnected from the ventilator during intra-facility transfers. Intentional and accidental circuit disconnections represent a potential hazard to patients (sudden collapse and re-expansion of the alveoli) as well as to clinical staff (exposure to patient's unfiltered exhalation). Therefore, avoiding abrupt circuit disconnections could better protect the patient's health and reduce or eliminate contamination risks around clinical staff.

objectiveThe purpose of this in-vitro work was to investigate and evaluate the potential for environmental exposure of Nitric Oxide (NO, as an indicator of any contamination exposure) before and after implementing the novel Flusso™ Bypass adapter during the disconnect procedure of a mechanical ventilator system.

methodsA mechanical ventilator delivering NO was connected to a breathing simulator with and without the Flusso™ Bypass adapter. The ambient NO concentration was measured when the circuit was briefly disconnected (3 s) during inhalation and exhalation. Both volume and pressure ventilation modes were used. MEASUREMENTS AND MAIN

resultsDisconnecting the standard ventilator circuit (pressure-controlled mode) without the Flusso™ Bypass adapter produced higher NO escape to the surroundings (compared with the volume-controlled mode), leading to a longer NO dissipation time. No ambient NO traces were detected when the Flusso™ adapter was used.

conclusionThe usage of the Flusso™ adapter drastically decreases the unwanted exposure among clinical staff dealing with potentially hazardous airborne biological aerosols emanating from the circuit. Avoiding abrupt disconnection in the ventilator circuit could reduce lung injuries and alveolar over distension and collapse.

Indexed as

circuit disconnectionFlusso™ Bypass adaptermechanical ventilationnitric oxide

Identifiers

PMID33313385
PMCPMC7724989

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.