Evidence map›Paper›PMID 33306164›Full record

ArticleAnnals of intensive care2020

Measurement site of inferior vena cava diameter affects the accuracy with which fluid responsiveness can be predicted in spontaneously breathing patients: a post hoc analysis of two prospective cohorts.

Morgan Caplan, Arthur Durand, Perrine Bortolotti, Delphine Colling, Julien Goutay, Thibault Duburcq, Elodie Drumez, Anahita Rouze, Saad Nseir, Michael Howsam and 3 more

Abstract read
In one paragraph

Article in Annals of intensive care, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 21 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
21citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

21 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Trial
  3. Article
  4. Review
  5. Review
  6. Article
  7. Review
  8. Article
  9. Easy method to determine fluid responsiveness in septic shock patients: end-tidal CO2 - a prospective observational study.Ulusal travma ve acil cerrahi dergisi = Turkish journal of trauma & emergency surgery : TJTES · 2024
    Observational
  10. Article
  11. Review
  12. Article
  13. Article
  14. Article
  15. Review
  16. Prediction of fluid responsiveness. What's new?Annals of intensive care · 2022
    Review
  17. Review
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors.

Morgan CaplanDivision of Intensive Care, University of Lille, CHU Lille, 59000, Lille, France.
Arthur DurandDivision of Intensive Care, University of Lille, CHU Lille, 59000, Lille, France.
Perrine BortolottiDivision of Intensive Care, University of Lille, CHU Lille, 59000, Lille, France.
Delphine CollingDivision of Intensive Care, University of Lille, CHU Lille, 59000, Lille, France.
Julien GoutayDivision of Intensive Care, University of Lille, CHU Lille, 59000, Lille, France.
Thibault DuburcqDivision of Intensive Care, University of Lille, CHU Lille, 59000, Lille, France.
Elodie DrumezDepartment of Biostatistics, BST. University of Lille, ULR 2694 - METRICS : Évaluation des Technologies de Santé et des Pratiques Méd icales, CHU Lille, 59000, Lille, France.
Anahita RouzeDivision of Intensive Care, University of Lille, CHU Lille, 59000, Lille, France.
Saad NseirDivision of Intensive Care, University of Lille, CHU Lille, 59000, Lille, France.
Michael HowsamUniversity of Lille, Inserm, Institut Pasteur de Lille, U1167, 59000, Lille, France.
Thierry OnimusDivision of Intensive Care, University of Lille, CHU Lille, 59000, Lille, France.
Raphael FavoryDivision of Intensive Care, University of Lille, CHU Lille, Inserm, Institut Pasteur de Lille, Hôpital Roger Salengro, U1167 Avenue Emile Laine, 59000, Lille, France.
Sebastien PreauDivision of Intensive Care, University of Lille, CHU Lille, Inserm, Institut Pasteur de Lille, Hôpital Roger Salengro, U1167 Avenue Emile Laine, 59000, Lille, France. seb.preau@gmail.com.ORCID http://orcid.org/0000-0002-8638-7183

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe collapsibility index of the inferior vena cava (cIVC) has potential for predicting fluid responsiveness in spontaneously breathing patients, but a standardized approach for measuring the inferior vena cava diameter has yet to be established. The aim was to test the accuracy of different measurement sites of inferior vena cava diameter to predict fluid responsiveness in spontaneously breathing patients with sepsis-related circulatory failure and examine the influence of a standardized breathing manoeuvre.

resultsAmong the 81 patients included in the study, the median Simplified Acute Physiologic Score II was 34 (24; 42). Sepsis was of pulmonary origin in 49 patients (60%). Median volume expansion during the 24 h prior to study inclusion was 1000 mL (0; 2000). Patients were not severely ill: none were intubated, only 20% were on vasopressors, and all were apparently able to perform a standardized breathing exercise. Forty-one (51%) patients were responders to volume expansion (i.e. a ≥ 10% stroke volume index increase). The cIVC was calculated during non-standardized (cIVC-ns) and standardized breathing (cIVC-st) conditions. The accuracy with which both cIVC-ns and cIVC-st predicted fluid responsiveness differed significantly by measurement site (interaction p < 0.001 and < 0.0001, respectively). Measuring inferior vena cava diameters 4 cm caudal to the right atrium predicted fluid responsiveness with the best accuracy. At this site, a standardized breathing manoeuvre also significantly improved predictive power: areas under ROC curves [mean and (95% CI)] for cIVC-ns = 0.85 [0.78-0.94] versus cIVC-st = 0.98 [0.97-1.0], p < 0.001. When cIVC-ns is superior or equal to 33%, fluid responsiveness is predicted with a sensitivity of 66% and a specificity of 92%. When cIVC-st is superior or equal to 44%, fluid responsiveness is predicted with a sensitivity of 93% and a specificity of 98%.

conclusionThe accuracy with which cIVC measurements predict fluid responsiveness in spontaneously breathing patients depends on both the measurement site of inferior vena cava diameters and the breathing regime. Measuring inferior vena cava diameters during a standardized inhalation manoeuvre at 4 cm caudal to the right atrium seems to be the method by which to obtain cIVC measurements best-able to predict patients' response to volume expansion.

Indexed as

Collapsibility indexEchocardiographyFluid responsivenessFluidsHemodynamicInferior vena cavaSepsisSevere infectionSpontaneous breathingUltrasound

Identifiers

PMID33306164
PMCPMC7732956

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.