Evidence map›Paper›PMID 33305060›Full record

ArticleArchives of medical sciences. Atherosclerotic diseases2020

The accuracy of distribution of non-ST elevation electrocardiographic changes in localising the culprit vessel in non-ST elevation myocardial infarction.

Kristina Gifft, Rugheed Ghadban, Nina Assefa, Zachary Luebbering, Haytham Allaham, Tariq Enezate

Open access · diamondAbstract read
In one paragraph

Article in Archives of medical sciences. Atherosclerotic diseases, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.1field-weighted citation impact, top 45% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 4 citations in OpenAlex.

  1. Clinical and Electrocardiographic Characteristics in NSTEMI Patients With Acute Total Occlusion of Culprit Left Circumflex Artery.Annals of noninvasive electrocardiology : the official journal of the International Society for Holter and Noninvasive Electrocardiology, Inc · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 4 institutions in 1 country.

Kristina GifftDepartment of General Medicine, University of Missouri Health Care, Columbia, MO, USA.
Rugheed GhadbanDivision of Cardiology, Washington University, St Louis, MO, USA.
Nina AssefaDivision of Cardiovascular Medicine, University of Missouri Health Care, Columbia, MO, USA.
Zachary LuebberingDivision of Cardiovascular Medicine, University of Missouri Health Care, Columbia, MO, USA.
Haytham AllahamDivision of Cardiology, University of Maryland, Baltimore, MD, USA.
Tariq EnezateDivision of Cardiology, University of California Log Angeles-Harbor Medical Center, Los Angeles, CA, USA.
University of Missouri Health System · USLos Angeles Medical Center · USUniversity of Maryland, Baltimore · USWashington University in St. Louis · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionST-segment elevation distribution on electrocardiogram (ECG) in patients presenting with ST-elevation myocardial infarction (STEMI) accurately localises the culprit vessel. However, the utility of the ECG changes in localising the coronary culprit territory in the setting of non-ST segment elevation myocardial infarction (NSTEMI) is not well established. MATERIAL AND

methodsThis study included patients presenting with NSTEMI, who had dynamic non-ST elevation ischaemic changes in one or more ECG leads and underwent percutaneous coronary intervention (PCI) in a single vessel between October 2011 and November 2017 in a single university hospital institution. The accuracy, sensitivity, and specificity of the distribution of ECG changes in localising the culprit vessel were calculated.

resultsThere was a total of 82 patients included in this study, who received PCI to the left anterior descending (LAD), right coronary artery (RCA), and left circumflex (LCX), in 43.9%, 24.4%, and 31.7%, respectively; 51% were male. In this cohort, sensitivity of ECG in localising single-culprit-vessel NSTEMI was 41.5%. The overall accuracy of ECG changes was 50.0%, 72.0%, and 70.0% in LAD, RCA, and LCX distribution, respectively. The sensitivity and specificity were 72.2% and 32.6% in LAD distribution, 20% and 88.7% in RCA distribution, and 15.4% and 82.1% in LCX distributions, respectively.

conclusionsIschaemic non-ST elevation ECG changes had modest accuracy in localising the culprit vessel in patients with PCI-treated NSTEMI. These changes were more sensitive in LAD distribution and more specific in RCA and LCX distributions.

Indexed as

coronary angiogramculprit vesselnon-ST elevation ischaemic changesnon-ST segment elevation myocardial infarction

Identifiers

PMID33305060
PMCPMC7717448
OpenAlexW3096140223

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.