Evidence map›Paper›PMID 33304608›Full record

ArticleGlobal challenges (Hoboken, NJ)2020

GlasVent-The Rapidly Deployable Emergency Ventilator.

Adamos Christou, Markellos Ntagios, Andrew Hart, Ravinder Dahiya

Open access · goldAbstract read
In one paragraph

Article in Global challenges (Hoboken, NJ), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
3.8field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 38 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Differential Pressure Spirometry for Mechanical Ventilation Using Dichotomic Search.IEEE transactions on instrumentation and measurement · 2021
    Article
  9. Review
  10. GlasVent-The Rapidly Deployable Emergency Ventilator.Global challenges (Hoboken, NJ) · 2020
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Adamos ChristouBendable Electronics and Sensing Technologies (BEST) Group University of Glasgow Glasgow G12 8QQ UK.
Markellos NtagiosBendable Electronics and Sensing Technologies (BEST) Group University of Glasgow Glasgow G12 8QQ UK.
Andrew HartGlasgow Royal Infirmary NHS Greater Glasgow and Clyde Glasgow G12 0XH UK.
Ravinder DahiyaBendable Electronics and Sensing Technologies (BEST) Group University of Glasgow Glasgow G12 8QQ UK.ORCID https://orcid.org/0000-0002-3858-3841
University of Glasgow · GBNHS Greater Glasgow and Clyde · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

As a result of the novel Coronavirus disease (COVID-19) outbreak, a surge is witnessed in the demand for mechanical ventilators needed for treating affected patients. With the rapidly virus spreading around the globe, the shortage of ventilators becomes a global challenge and numerus efforts are followed. While industry mobilizes toward producing medical grade equipment, a number of low-cost and less complex emergency ventilators have been developed, mainly through academic and open-source channels, with a hope to meet any temporary needs gap until medical grade ventilator provision becomes sufficient. Herein, the design and implementation of one such emergency ventilator called GlasVent is presented, which an automated version of manual resuscitator device, commonly known as big valve mask or artificial manual breathing unit bag and widely used prior to initiating the mechanical ventilation. GlasVent uses 3D printed mechanical parts, widely available materials and off-the-shelf electronic and sensing devices which can be fast assembled. Furthermore, it requires minimal training and can be operated manually by hands or legs, thus meeting the emergency requirements even in the low-resource settings or regions with less developed healthcare systems. Post-COVID-19, such ventilators can potentially find use in clinical care of a wider variety of patients with injury, pulmonary noncommunicable diseases, and severe asthma etc.

Indexed as

3D Printingcovid‐19DIYhealthcare technologyventilators

Identifiers

PMID33304608
PMCPMC7713554
OpenAlexW3084293685

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.