Evidence map›Paper›PMID 33301541›Full record

ArticlePloS one2020

Intra- and inter-rater reliability of joint range of motion tests using tape measure, digital inclinometer and inertial motion capturing.

Laura Fraeulin, Fabian Holzgreve, Mark Brinkbäumer, Anna Dziuba, David Friebe, Stefanie Klemz, Marco Schmitt, Anna-Lena Theis A, Sarah Tenberg, Anke van Mark and 2 more

2 registry-linked trialsAbstract read
In one paragraph

Article in PloS one, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 2 registered trials, which are not on this map. Cited by 16 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
16citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT05214456 naunknown statusnot on this mapstarted 2022, after this paper: background citation

To Compare the Effect of Dry Needling Versus Lumbar Spine Mobilization on Symptoms in Patients With Chronic Nonspecific Low Back Pain

TypeinterventionalSponsorIran University of Medical SciencesRan2022 to 2023Enrolled56ConditionsLow Back PainArmsDry needling, Mobilization
NCT06479538 nacompletednot on this mapstarted 2023, after this paper: background citation

Comparative Effects of Post Isometric Relaxation and Post Facilitation Stretching on Pain, Rom and Functional Disability Among Young Fast Bowlers With Quadratus Lumborum Tightness

TypeinterventionalSponsorRiphah International UniversityRan2023 to 2024Enrolled34ConditionsSports Physical TherapyArmsPost isometric relaxation, Post facilitation stretching
3 · Its place in the literature

Who cites it

16 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Trial
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Observational
  14. Article
  15. Article
  16. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Laura FraeulinInstitute for Occupational Medicine, Social Medicine and Environment Medicine, Goethe-University Frankfurt, Frankfurt am Main, Germany.ORCID 0000-0001-5214-5963
Fabian HolzgreveInstitute for Occupational Medicine, Social Medicine and Environment Medicine, Goethe-University Frankfurt, Frankfurt am Main, Germany.
Mark BrinkbäumerInstitute of Sports Sciences, Goethe-University Frankfurt, Frankfurt am Main, Germany.
Anna DziubaInstitute of Sports Sciences, Goethe-University Frankfurt, Frankfurt am Main, Germany.
David FriebeInstitute of Sports Sciences, Goethe-University Frankfurt, Frankfurt am Main, Germany.
Stefanie KlemzInstitute of Sports Sciences, Goethe-University Frankfurt, Frankfurt am Main, Germany.
Marco SchmittInstitute of Sports Sciences, Goethe-University Frankfurt, Frankfurt am Main, Germany.
Anna-Lena Theis AInstitute of Sports Sciences, Goethe-University Frankfurt, Frankfurt am Main, Germany.
Sarah TenbergInstitute of Sports Sciences, Goethe-University Frankfurt, Frankfurt am Main, Germany.
Anke van MarkInstitute for Occupational Medicine, Social Medicine and Environment Medicine, Goethe-University Frankfurt, Frankfurt am Main, Germany.
Christian Maurer-GrubingerInstitute for Occupational Medicine, Social Medicine and Environment Medicine, Goethe-University Frankfurt, Frankfurt am Main, Germany.ORCID 0000-0002-8426-813X
Daniela OhlendorfInstitute for Occupational Medicine, Social Medicine and Environment Medicine, Goethe-University Frankfurt, Frankfurt am Main, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundIn clinical practice range of motion (RoM) is usually assessed with low-cost devices such as a tape measure (TM) or a digital inclinometer (DI). However, the intra- and inter-rater reliability of typical RoM tests differ, which impairs the evaluation of therapy progress. More objective and reliable kinematic data can be obtained with the inertial motion capture system (IMC) by Xsens. The aim of this study was to obtain the intra- and inter-rater reliability of the TM, DI and IMC methods in five RoM tests: modified Thomas test (DI), shoulder test modified after Janda (DI), retroflexion of the trunk modified after Janda (DI), lateral inclination (TM) and fingertip-to-floor test (TM).

methodsTwo raters executed the RoM tests (TM or DI) in a randomized order on 22 healthy individuals while, simultaneously, the IMC data (Xsens MVN) was collected. After 15 warm-up repetitions, each rater recorded five measurements.

findingsIntra-rater reliabilities were (almost) perfect for tests in all three devices (ICCs 0.886-0.996). Inter-rater reliability was substantial to (almost) perfect in the DI (ICCs 0.71-0.87) and the IMC methods (ICCs 0.61-0.993) and (almost) perfect in the TM methods (ICCs 0.923-0.961). The measurement error (ME) for the tests measured in degree (°) was 0.9-3.3° for the DI methods and 0.5-1.2° for the IMC approaches. In the tests measured in centimeters the ME was 0.5-1.3cm for the TM methods and 0.6-2.7cm for the IMC methods. Pearson correlations between the results of the DI or the TM respectively with the IMC results were significant in all tests except for the shoulder test on the right body side (r = 0.41-0.81).

interpretationMeasurement repetitions of either one or multiple trained raters can be considered reliable in all three devices.

Indexed as

Range of Motion, ArticularAdultBiomechanical PhenomenaFemaleHumansMaleObserver VariationPhysical ExaminationProspective StudiesYoung Adult

Identifiers

PMID33301541
PMCPMC7728246

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials