Evidence map›Paper›PMID 33301060›Full record

ArticleCVIR endovascular2020

Temperature-induced configuration changes in hydrogel-coated coils and their relevance in embolization procedures.

Ruben Lopez Benitez, Tomas Reyes Del Castillo, Levent Kara, Joachim Kettenbach, Justus Roos

Abstract read
In one paragraph

Article in CVIR endovascular, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Ruben Lopez BenitezDepartment of Radiology and Nuclear Medicine, Luzerner Kantonsspital, 6000, Luzern, Switzerland. ruben.lopezbenitez@luks.ch.
Tomas Reyes Del CastilloDepartment of Radiology and Nuclear Medicine, Luzerner Kantonsspital, 6000, Luzern, Switzerland.
Levent KaraStadtspital Triemli Zürich, Institute of Radiology and Nuclear Medicine, 8063, Zurich, Switzerland.
Joachim KettenbachZentralröntgeninstitut für Diagnostik, Interventionelle Radiologie und Nuklearmedizin, Landesklinikum Wiener Neustadt, 2700, Wiener Neustadt, Austria.
Justus RoosDepartment of Radiology and Nuclear Medicine, Luzerner Kantonsspital, 6000, Luzern, Switzerland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe present study attempted to demonstrate how the configuration of hydrogel-coated coils is influenced by different temperature exposures. Thirty detachable hydrogel-coated coils were evaluated in an in vitro water immersion test under five different temperature ranges (22.6 °C, 37 °C, 40-50 °C, 50-60 °C, and 60-70 °C). The configuration changes were classified (configuration I, configuration II, and configuration III) according to the curling that occurred during 30 min of immersion. Configuration stability of five Hydrogel-coated coils was also evaluated in a two-step temperature immersion test.

resultsAll hydrogel-coated coils showed some configuration changes during water immersion. However, a logarithmic transformation of the time and temperature data showed a significant (p < 0.05) negative linear correlation between time and temperature for all coil configurations (configuration I: R = 0.97, configuration II: R = 0.98, configuration III: R = 0.97). The time needed to reach configuration III (complete coiling) was 160.4 ± 41.9 s at 37.5 °C (range: 100-205 s), 45.7 ± 22.2 s at 47.5 °C (range: 23-70 s), 20.2 ± 7.2 s at 57.5 °C (range: 14-32 s), and 10.3 ± 2.4 s at 67.5 °C (range: 7-13 s).

conclusionsTemperatures above 55 °C induced immediate configurational changes in the hydro-coated coils, achieving complete curling within less than 30 s. Temperatures near 36 °C (normal body temperature) require more time to reach optimal coil curling (configuration III). The optimization of HydroCoil preparation can reduce interventional procedural time and improve clinical results.

Indexed as

Coil optimizationEmbolization proceduresHydro-coated coilsInterventional radiologyTemperature-induced configurationWater immersion

Identifiers

PMID33301060
PMCPMC7728940

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.