Using Cherenkov imaging to monitor the match line between photon and electron radiation therapy fields on biological tissue phantoms.

Yi Li, Hongjun Liu, Nan Huang, Zhaolu Wang, Chunmin Zhang

Abstract read
In one paragraph

Article in Journal of biomedical optics, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Yi LiChinese Academy of Sciences, Xi'an Institute of Optics and Precision Mechanics, State Key Laboratory, China.
Hongjun LiuChinese Academy of Sciences, Xi'an Institute of Optics and Precision Mechanics, State Key Laboratory, China.
Nan HuangChinese Academy of Sciences, Xi'an Institute of Optics and Precision Mechanics, State Key Laboratory, China.
Zhaolu WangChinese Academy of Sciences, Xi'an Institute of Optics and Precision Mechanics, State Key Laboratory, China.
Chunmin ZhangXi'an Jiaotong University, School of Physics, Xi'an, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

significanceDue to patients' respiratory movement or involuntary body movements during breast cancer radiotherapy, the mismatched adjacent fields in surface exposure regions could result in insufficient dosage or overdose in these regions, which would lead to tissue injury, excessive skin burns, and potential death. Cherenkov luminescence imaging (CLI) could be used to effectively detect the matching information of adjacent radiation fields without extra radiation or invasive imaging.

aimOur objective was to provide a biological experimental basis for monitoring matching of adjacent radiation fields between photon and electron fields due to introduced shifts during radiotherapy by CLI technique. APPROACH: A medical accelerator was used to generate photon and electron fields. An industrial camera system was adopted to image the excited CLI signal during irradiation of chicken tissue with yellow (group A and group C experiments) or black color (group B experiment). The following introduced shifts were tested: 10, 5, 2, and 0 mm toward superior or inferior direction. A model was introduced to deal with matching error analysis of adjacent radiation fields due to introduced shifts with adapted plans used to treat neoplasms of the right breast with supraclavicular nodes or internal mammary lymph node.

resultsThe matching values between photon and electron fields were consistent with the tested introduced shifts during yellow chicken irradiation. In group A, average discrepancies were 0.59  ±  0.35  mm and 0.68  ±  0.37  mm for photon fields and electron fields in anterior/posterior (AP) direction, with 87% and 75% of measurement within 1 mm, respectively. In group C, average discrepancies were 0.80  ±  0.65  mm and 1.07  ±  0.57  mm for oblique photon field with gantry angles of 330 deg and 150 deg, with 66% and 65% of measurement within 1 mm, respectively. The average discrepancies were 0.44  ±  0.30  mm for electron field in the AP direction, with 94% of measurement within 1 mm. The matching error introduced by the proposed method was less than 1.5 mm for AP fields and 2 mm for oblique incidence fields. However, the field matching could not be monitored with black chicken tissue irradiation due to a weak CLI signal that could hardly be extracted from background noise in group B.

conclusionsCLI is demonstrated for the quantitative monitoring of the field match line on light biological tissue phantoms and has potential for monitoring of field matching in surface tissue during breast cancer radiotherapy.

Indexed as

Breast NeoplasmsElectronsDiagnostic ImagingFemaleHumansPhantoms, ImagingPhotonsRadiotherapy DosageRadiotherapy Planning, Computer-Assistedbiological tissuecharge-coupled deviceCherenkov luminescence imagingfield matchingradiotherapy

Identifiers

PMID33300317
PMCPMC7725107

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.