Evidence map›Paper›PMID 33299915›Full record

ArticleArthroplasty today2020

Lewinnek Safe Zone References are Frequently Misquoted.

Aonnicha Burapachaisri, Ameer Elbuluk, Edem Abotsi, Jim Pierrepont, Seth A Jerabek, Aaron J Buckland, Jonathan M Vigdorchik

Abstract read
In one paragraph

Article in Arthroplasty today, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Review
  3. Article
  4. Polyethylene liner dissociation in total hip arthroplasty: a retrospective case-control study on a single implant design.Journal of orthopaedics and traumatology : official journal of the Italian Society of Orthopaedics and Traumatology · 2024
    Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Aonnicha BurapachaisriDivision of Spine Surgery, Department of Orthopaedic Surgery, NYU Langone Orthopedic Hospital, New York, NY, USA.
Ameer ElbulukAdult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, NY, USA.
Edem AbotsiDivision of Spine Surgery, Department of Orthopaedic Surgery, NYU Langone Orthopedic Hospital, New York, NY, USA.
Jim PierrepontChief Innovation Officer, Corin Group, New South Wales, Australia.
Seth A JerabekAdult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, NY, USA.
Aaron J BucklandDivision of Spine Surgery, Department of Orthopaedic Surgery, NYU Langone Orthopedic Hospital, New York, NY, USA.
Jonathan M VigdorchikAdult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, NY, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundOptimal acetabular component orientation in total hip arthroplasty (THA) is a necessity in achieving a stable implant. Although there has been considerable debate in the literature concerning the safe zone, to date, there has not been any review to determine if these references are consistent with the definition applied by Lewinnek et al. in 1978. Therefore, this article aims to examine the available literature in the PubMed database to determine how often a correct reference to the safe zone as defined by Lewinnek was applied to discussions regarding THA.

methodsA search for literature in the PubMed database was performed for articles from 1978 to 2019. Search criteria included terms 'Lewinnek,' 'safe zone,' and 'total hip arthroplasty.' Exclusions included abstract-only articles, non-English articles, articles unrelated to THA, and those lacking full content.

resultsA review of literature yielded 147 articles for inclusion. Overall, only 11% (17) cited the Lewinnek article correctly. Forty-five percent (66) of articles referenced measurements in the supine position, 18% (26) referenced other positions, and 37% (55) did not specify. Nineteen percent (28) reported measurements of the acetabular cup orthogonal to the anterior pelvic plane, while 73% (108) did not, and 7% (11) did not specify. Twenty-three percent (34) measured from computed tomography scans instead of other methods.

conclusionsIn the discussion of the safe zone regarding THA, only 11% of articles listed are consistent with the definition established by Lewinnek. This warrants further investigation into a consistent application of the term and its implications for THA implant stability and dislocation rates.

Indexed as

Anterior pelvic planeAnteversionInclinationLewinnekSafe zoneTotal hip arthroplasty

Identifiers

PMID33299915
PMCPMC7701843

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.