Probe Electrospray Ionization (PESI) and Its Modified Versions: Dipping PESI (dPESI), Sheath-Flow PESI (sfPESI) and Adjustable sfPESI (ad-sfPESI).

Kenzo Hiraoka, Osamu Ariyada, Dilshadbek T Usmanov, Lee C Chen, Satoshi Ninomiya, Kentaro Yoshimura, Sen Takeda, Zhang Yu, Mridul K Mandal, Hiroshi Wada and 2 more

Abstract read
In one paragraph

Article in Mass spectrometry (Tokyo, Japan), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Observational
  2. Article
  3. RSC advances · 2024
    Article
  4. Review
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Kenzo HiraokaClean Energy Research Center, University of Yamanashi, 4-3-11 Takeda, Kofu 400-8511, Japan.
Osamu AriyadaARIOS INC., 3-2-20 Musashino, Akishima, Tokyo 196-0021, Japan.
Dilshadbek T UsmanovClean Energy Research Center, University of Yamanashi, 4-3-11 Takeda, Kofu 400-8511, Japan.
Lee C ChenGraduate Faculty of Interdisciplinary Research, University of Yamanashi, 4-3-11 Takeda, Kofu 400-8511, Japan.
Satoshi NinomiyaGraduate Faculty of Interdisciplinary Research, University of Yamanashi, 4-3-11 Takeda, Kofu 400-8511, Japan.
Kentaro YoshimuraDepartment of Anatomy and Cell Biology, Faculty of Medicine, University of Yamanashi, 1110 Shimo-Kateau, Chuo, Yamanashi 409-3898, Japan.
Sen TakedaDepartment of Anatomy and Cell Biology, Faculty of Medicine, University of Yamanashi, 1110 Shimo-Kateau, Chuo, Yamanashi 409-3898, Japan.
Zhang YuClean Energy Research Center, University of Yamanashi, 4-3-11 Takeda, Kofu 400-8511, Japan.
Mridul K MandalClean Energy Research Center, University of Yamanashi, 4-3-11 Takeda, Kofu 400-8511, Japan.
Hiroshi WadaKyushu Okinawa Agricultural Research Center, National Agricultural and Food Research Organization, 496 Izumi, Chikugo, Fukuoka 833-0041, Japan.
Stephanie Rankin-TurnerClean Energy Research Center, University of Yamanashi, 4-3-11 Takeda, Kofu 400-8511, Japan.
Hiroshi NonamiPlant Biophysics/Biochemistry Research Laboratory, Faculty of Agriculture, Ehime University, Matsuyama 790-8566, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In 2007, probe electrospray ionization/mass spectrometry (PESI/MS) was developed. In this technique, the needle is moved down along a vertical axis and the tip of the needle touched to the sample. After capturing the sample at the needle tip, the needle is then moved up and a high voltage is applied to the needle at the highest position to generate electrospray. Due to the discontinuous sampling followed by the generation of spontaneous electrospray, sequential and exhaustive electrospray takes place depending on the surface activity of the analytes. As modified versions of PESI, dipping PESI (dPESI), sheath-flow PESI (sfPESI) and adjustable sfPESI (ad-sfPESI) have been developed. These methods are complementary to each other and they can be applicable to surface and bulk analysis of various biological samples. In this article, the characteristics of these methods and their applications to real samples will be reviewed.

Indexed as

point analysisprobe electrospray ionization (PESI)robotic mass spectrometrysurface analysis

Identifiers

PMID33299735
PMCPMC7708747

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.