ArticleMicrosystems & nanoengineering2020
MRBLES 2.0: High-throughput generation of chemically functionalized spectrally and magnetically encoded hydrogel beads using a simple single-layer microfluidic device.
Article in Microsystems & nanoengineering, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed.
- Decoupling Fabrication From Encoding: DNA-Addressable Template Microparticles for Large, User-Defined Optical Barcode Libraries.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026Article
- Thermo-Responsive Living Microspheroids Enable a Regenerative Living Disk-Drive System for DNA Data Storage.Advanced materials (Deerfield Beach, Fla.) · 2026Article
- Encoded Microspheres in Multiplex Detection of Mycotoxins and Other Analytes.Foods (Basel, Switzerland) · 2026Review
- Bioinspired Metal-Ligand Networks with Enhanced Stability and Performance: Facile Preparation of Hydroxypyridinone (HOPO)-Functionalized Materials.Macromolecules · 2024Article
- Concave Magnetic-Responsive Hydrogel Discs for Enhanced Bioassays.Biosensors · 2024Article
- Phosphatase specificity principles uncovered by MRBLE:Dephos and global substrate identification.Molecular systems biology · 2023Article
- Identification of fluorescently-barcoded nanoparticles using machine learning.Nanoscale advances · 2023Article
- I-LIFT (image-based laser-induced forward transfer) platform for manipulating encoded microparticles.Biomicrofluidics · 2022Article
- A bead-based method for high-throughput mapping of the sequence- and force-dependence of T cell activation.Nature methods · 2022Article
- Tuning T cell receptor sensitivity through catch bond engineering.Science (New York, N.Y.) · 2022Article
- MRBLE-pep Measurements Reveal Accurate Binding Affinities for B56, a PP2A Regulatory Subunit.ACS measurement science au · 2021Article
- Magnetic Particles for CTC Enrichment.Cancers · 2020Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
The widespread adoption of bead-based multiplexed bioassays requires the ability to easily synthesize encoded microspheres and conjugate analytes of interest to their surface. Here, we present a simple method (MRBLEs 2.0) for the efficient high-throughput generation of microspheres with ratiometric barcode lanthanide encoding (MRBLEs) that bear functional groups for downstream surface bioconjugation. Bead production in MRBLEs 2.0 relies on the manual mixing of lanthanide/polymer mixtures (each of which comprises a unique spectral code) followed by droplet generation using single-layer, parallel flow-focusing devices and the off-chip batch polymerization of droplets into beads. To streamline downstream analyte coupling, MRBLEs 2.0 crosslinks copolymers bearing functional groups on the bead surface during bead generation. Using the MRBLEs 2.0 pipeline, we generate monodisperse MRBLEs containing 48 distinct well-resolved spectral codes with high throughput (>150,000/min and can be boosted to 450,000/min). We further demonstrate the efficient conjugation of oligonucleotides and entire proteins to carboxyl MRBLEs and of biotin to amino MRBLEs. Finally, we show that MRBLEs can also be magnetized via the simultaneous incorporation of magnetic nanoparticles with only a minor decrease in the potential code space. With the advantages of dramatically simplified device fabrication, elimination of the need for custom-made equipment, and the ability to produce spectrally and magnetically encoded beads with direct surface functionalization with high throughput, MRBLEs 2.0 can be directly applied by many labs towards a wide variety of downstream assays, from basic biology to diagnostics and other translational research.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.