Evidence map›Paper›PMID 33298115›Full record

ArticleJournal of orthopaedic surgery and research2020

Influence of a metaphyseal sleeve on the stress-strain state of a bone-tumor implant system in the distal femur: an experimental and finite element analysis.

Jian-Jun Li, Dong-Mu Tian, Li Yang, Jing-Yu Zhang, Yong-Cheng Hu

Open access · goldAbstract read
In one paragraph

Article in Journal of orthopaedic surgery and research, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
0.8field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 11 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 1 country.

Jian-Jun LiTianjin Medical University, 22 Qixiangtai Road, Tianjin, People's Republic of China.
Dong-Mu TianBeijing Weigao Yahua Artificial Joint Development Company, 7 Niuhui Street, Shunyi, Beijing, People's Republic of China.
Li YangTianjin Medical University, 22 Qixiangtai Road, Tianjin, People's Republic of China.
Jing-Yu ZhangDepartment of Bone Oncology, Second Hospital of Tangshan, 22 Jianshe North Road, Tangshan, Hebei, People's Republic of China.
Yong-Cheng HuDepartment of Bone Oncology, Tianjin Hospital, 406 Jiefang Southern Road, Tianjin, People's Republic of China. huycdoctor@163.com.ORCID https://orcid.org/0000-0002-9846-6735
Second Hospital of Tangshan · CNTianjin Medical University · CNTianjin People's Hospital · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAseptic loosening of distal femoral tumor implants significantly correlates with the resection length. We designed a new "sleeve" that is specially engaged in the metaphysis at least 5 cm proximal to the knee joint line to preserve as much bone stock as possible. This study investigates the influence of a metaphyseal sleeve on the stress-strain state of a bone tumor implant system in the distal femur.

methodsCortex strains in intact and implanted femurs were predicted with finite element (FE) models. Moreover strains were experimentally measured in a cadaveric femur with and without a sleeve and stem under an axial compressive load of 1000 N. The FE models, which were validated by linear regression, were used to investigate the maximal von Mises stress and the implanted-to-intact (ITI) ratios of strain in the femur with single-legged stance loading under immediate postoperative and osseointegration conditions.

resultsGood agreement was noted between the experimental measurements and numerical predictions of the femoral strains (coefficient of determination (R

conclusionsThis study reveals that a metaphyseal sleeve may cause stress shielding relative to the intact femur, especially in the distal metaphysis. Stress concentrations might mainly occur in the posterior cortex around the tip of the stem. However, stress concentrations may not be accompanied by periprosthetic fracture under the single-legged stance condition.

Indexed as

Finite Element AnalysisProsthesis DesignAgedBiomechanical PhenomenaBone-Implant InterfaceBone NeoplasmsCadaverFemaleFemurHumansOrthopedic ProceduresOsseointegrationPlastic Surgery ProceduresProstheses and ImplantsStress, MechanicalDistal femurFinite-element analysisSleeveStrain gaugeStress shielding

Identifiers

PMID33298115
PMCPMC7724731
OpenAlexW3113344741

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.