Evidence map›Paper›PMID 33294999›Full record

ArticleMedical physics2021

7T MR Thermometry technique for validation of system-predicted SAR with a home-built radiofrequency wrist coil.

Andrew J Fagan, Paul S Jacobs, Thomas C Hulshizer, Phillip J Rossman, Matthew A Frick, Kimberly K Amrami, Joel P Felmlee

Open access · greenAbstract read
In one paragraph

Article in Medical physics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.2field-weighted citation impact, top 52% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 5 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Andrew J FaganDepartment of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA.
Paul S JacobsDepartment of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA.
Thomas C HulshizerDepartment of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA.
Phillip J RossmanDepartment of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA.
Matthew A FrickDepartment of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA.
Kimberly K AmramiDepartment of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA.
Joel P FelmleeDepartment of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA.
Mayo Clinic · US

Funding

Post-baccalaureate Training in Biomedical ResearchR25GM075148 · NIGMS · MAYO CLINIC ROCHESTER · PI LUJAN, LUIS, MAHER, LOUIS JAMES · 2006 to 2024
$6.1M
HHS | NIH | National Institute of General Medical Sciences (NIGMS) 5 R25 GM075148NIGMS NIH HHS R25 GM075148
6 · The paper itself

Abstract

purposeA 7T magnetic resonance thermometry (MRT) technique was developed to validate the conversion factor between the system-measured transmitted radiofrequency (RF) power into a home-built RF wrist coil with the system-predicted SAR value. The conversion factor for a new RF coil developed for ultra high magnetic field MRI systems is used to ensure that regulatory limits on RF energy deposition in tissue, specifically the local 10g-averaged specific absorption rate (SAR

methodsA 14-cm diameter high-pass birdcage RF coil was built to image the wrist at 7T. A high spatial and temporal resolution dual-echo gradient echo MRT technique, incorporating quasi-simultaneous RF-induced heating and temperature change measurements using the proton resonance frequency method, was developed. The technique allowed for high-temperature resolution measurements (~±0.1°C) to be performed every 20 s over a 4-min heating period, with high spatial resolution (2.56 mm

resultsTemperature change measurements from MRT matched closely to those from the fiber optic temperature sensors. The simulations were validated via close correlation between the simulated and MRT-measured B

conclusionsA highly accurate MRT technique with high spatial and temporal resolution was developed. This technique can be used to ensure that system-predicted SAR values are not exceeded in practice, thereby providing independent validation of SAR levels delivered by a newly built RF wrist coil. The MRT technique is readily generalizable to perform safety evaluations for other RF coils at 7T.

Indexed as

ThermometryWristMagnetic Resonance ImagingPhantoms, ImagingRadio Waves7T MR Thermometrydevelopment (new technology and techniques)local SARphantoms - physicalquantitative imaging analysisRF coil safety

Identifiers

PMID33294999
PMCPMC8051816
OpenAlexW3110915181

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.