Evidence map›Paper›PMID 33293810›Full record

ArticleInternational journal of nanomedicine2020

Assessing Tensile Bond Strength Between Denture Teeth and Nano-Zirconia Impregnated PMMA Denture Base.

Saleh Zidan, Nikolaos Silikas, Julfikar Haider, Abdulaziz Alhotan, Javad Jahantigh, Julian Yates

Abstract read
In one paragraph

Article in International journal of nanomedicine, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Advanced materials and technologies for oral diseases.Science and technology of advanced materials · 2023
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Saleh ZidanDentistry, School of Medical Sciences, University of Manchester, Manchester M13 9PL, UK.
Nikolaos SilikasDentistry, School of Medical Sciences, University of Manchester, Manchester M13 9PL, UK.ORCID 0000-0003-4576-4584
Julfikar HaiderDepartment of Engineering, Manchester Metropolitan University, Manchester M1 5GD, UK.ORCID 0000-0001-7010-8285
Abdulaziz AlhotanDentistry, School of Medical Sciences, University of Manchester, Manchester M13 9PL, UK.ORCID 0000-0002-9036-0485
Javad JahantighDentistry, School of Medical Sciences, University of Manchester, Manchester M13 9PL, UK.ORCID 0000-0003-1260-4330
Julian YatesDentistry, School of Medical Sciences, University of Manchester, Manchester M13 9PL, UK.ORCID 0000-0002-8187-023X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThis study evaluated tensile bond strength (TBS) between anterior acrylic teeth and denture bases made of high-impact heat-cured acrylic resin (HI PMMA) impregnated with zirconia nanoparticles. MATERIALS AND

methodsA total of 30 specimens (each specimen containing a set of six upper anterior teeth) were fabricated from HI PMMA denture base acrylic resin reinforced with different weight concentrations of zirconia nanoparticles: 0% (control), 1.5%, 3%, 5%, 7% and 10%. TBS was tested according to a British standard (BS EN ISO 22112: 2017). A one-way analysis of variance (ANOVA) was employed with a Tukey post-hoc test.

resultsTBS values between the anterior teeth (central and lateral incisors and canine) and HI-PMMA denture base groups containing 7 wt.% (261.5 ± 66.0 N, 172.5 ± 57.4 N and 271.9 ± 86.3 N) and 10 wt.% (332.1 ± 122.9 N, 165.4 ± 48.7 N and 301.6 ± 73.2 N) zirconia were significantly lower compared to the control group (645.4 ± 84.8 N, 306.1 ± 81.6 N and 496.7 ± 179.1 N) and the other nanocomposite groups. However, TBS values for HI PMMA with 1.5 wt.% (534.4 ± 115.3 N, 304.7 ± 86.4 N, 514.0 ± 143.2 N), 3 wt.% (685.7 ± 159.6 N, 281.1 ± 78.3 N, 462.6 ± 122.1 N) and 5 wt.% (514.5 ± 134.3 N, 229.8 ± 67.3 N, 387.2 ± 99.4 N) zirconia showed slightly lower values than that of the control group but these were not significant. Failure modes between the teeth and denture base nanocomposites were predominantly cohesive fractures, which were clinically acceptable according to the Standard.

conclusionThe addition of zirconia nanoparticles to HI PMMA denture base at high concentration (7 wt.% and 10 wt. %) significantly (p<0.05) reduced the bonding strength for all types of anterior teeth compared to the control group.

Indexed as

Denture BasesAcrylic ResinsDental BondingDental Stress AnalysisMaterials TestingMetal NanoparticlesPolymethyl MethacrylateTensile StrengthZirconiumAcrylic ResinsPolymethyl MethacrylateZirconiumzirconium oxidedenturefailure modenanocompositePMMAtensile bond strength; TBSzirconia; ZrO2

Identifiers

PMID33293810
PMCPMC7718964

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.