Evidence map›Paper›PMID 33292851›Full record

ArticleInternational journal of retina and vitreous2020

Autologous full-thickness retinal transplant for refractory large macular holes.

Sergio Rojas-Juárez, Javier Cisneros-Cortés, Abel Ramirez-Estudillo, Raul Velez-Montoya

Open access · goldAbstract read
In one paragraph

Article in International journal of retina and vitreous, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed, 1 pooled it
1.4field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 1 synthesis or guideline pooled it, 25 citations in OpenAlex.

  1. Optimal approaches for managing recurrent macular holes: a comprehensive systematic review and meta-analysis.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2025
    Pooled it
  2. Article
  3. Article
  4. Article
  5. Review
  6. Tuck-in tenon patch graft for giant full-thickness macular holes.International journal of retina and vitreous · 2024
    Article
  7. Update on surgical management of complex macular holes: a review.International journal of retina and vitreous · 2021
    Review
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Sergio Rojas-JuárezRetina Department, Hospital de Nuestra Señora de La Luz, 06030, Mexico City, Mexico.
Javier Cisneros-CortésRetina Department, Hospital de Nuestra Señora de La Luz, 06030, Mexico City, Mexico.
Abel Ramirez-EstudilloRetina Department, Hospital de Nuestra Señora de La Luz, 06030, Mexico City, Mexico.
Raul Velez-MontoyaRetina Department, Asociación para Evitar le Ceguera en México IAP, Vicente García Torres #46. Col: San Lucas Coyoacán, 04030, Mexico City, Mexico. rvelezmx@yahoo.com.ORCID http://orcid.org/0000-0002-6457-4578
Asociacion Para Evitar la Ceguera en México Hospital Dr. Luis Sánchez Bulnes · MX

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundDespite the constant refinement of techniques and surgical aids, extremely large and refractory macular holes continue to have poor surgical outcomes with the current standard of care. The objective of the present study is to assess the anatomical and functional outcomes, as well as the structural change through time, of the optical coherence tomography of patients with refractory macular holes treated with a full-thickness autologous retinal transplant.

methodsProspective, case series. We include patients with a clinical diagnosis of refractory macular holes with a minimum diameter of at least 500 µm. All the patients had a comprehensive ophthalmological examination, which included a best-corrected visual acuity assessment, fundus examination, and optical coherence analysis. All the patients underwent a 23-gauge pars plana vitrectomy with a full-thickness retinal transplant and silicone oil tamponade (5000 cs<). Follow-up was done at 1, 3, 6, and 12 months. Statistical analysis was done with a test for repeated measurements and Bonferroni correction, with an alpha value of 0.05 for statistical significance and a Mann-Whitney U test for nonparametric continuous variables.

resultsWe enrolled 13 eyes from 13 patients (mean age: 67.15 years) with refractory macular holes, with a mean base diameter of 1615.38 ± 689.19 µm and a minimum diameter of 964.08 ± 709.77 µm. The closure rate after 12 months of follow-up was 76.92%. Six patients with a closed macular hole at the end of the follow-up had complete recovery of the myoid/ellipsoid layer. The remaining showed a 44.9% reduction of the initial gap. Most patients formed a pseudofovea and normalization of the internal retinal layers. Despite a positive trend toward visual recovery (p = 0.034), after the correction of the alpha value, the change lost its statistical significance. During follow-up, one patient developed mild proliferative vitreoretinopathy and epiretinal membrane without anatomical or functional consequences.

conclusionsAn autologous full-thickness retinal transplant may improve the anatomical and structural outcome of patients with refractory macular holes. The full safety profile of this new technique is still unknown. More studies are needed in order to assess functional changes through time.

Indexed as

Autologous retinal transplantLarge macular holeMacular holeRefractory macular holeRetina free patch

Identifiers

PMID33292851
PMCPMC7685585
OpenAlexW3108738664

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.