Evidence map›Paper›PMID 33287828›Full record

ArticleRadiation oncology (London, England)2020

Simplified sigmoidal curve fitting for a 6 MV FFF photon beam of the Halcyon to determine the field size for beam commissioning and quality assurance.

Min-Geon Choi, Martin Law, Do-Kun Yoon, Mikoto Tamura, Kenji Matsumoto, Masakazu Otsuka, Moo-Sub Kim, Shih-Kien Djeng, Hajime Monzen, Tae Suk Suh

Abstract read
In one paragraph

Article in Radiation oncology (London, England), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Min-Geon ChoiDepartment of Biomedical Engineering and Research Institute of Biomedical Engineering, College of Medicine, The Catholic University of Korea, Seoul, 06591, Republic of Korea.
Martin LawProton Therapy Pte Ltd., 1 Biopolis Drive, Singapore, 138622, Singapore.
Do-Kun YoonDepartment of Biomedical Engineering and Research Institute of Biomedical Engineering, College of Medicine, The Catholic University of Korea, Seoul, 06591, Republic of Korea.
Mikoto TamuraDepartment of Medical Physics, Graduate School of Medical Sciences, Kindai University, Osaka-Sayama-Shi, 377-2, Ohno-Higashi, Osaka-Sayama-Shi, Osaka, 589-8511, Japan.
Kenji MatsumotoDepartment of Radiology, Kindai University Hospital, Osaka-Sayama-Shi, 377-2, Ono-Higashi, Osaka-Sayama-Shi, Osaka, 589-8511, Japan.
Masakazu OtsukaDepartment of Medical Physics, Graduate School of Medical Sciences, Kindai University, Osaka-Sayama-Shi, 377-2, Ohno-Higashi, Osaka-Sayama-Shi, Osaka, 589-8511, Japan.
Moo-Sub KimDepartment of Biomedical Engineering and Research Institute of Biomedical Engineering, College of Medicine, The Catholic University of Korea, Seoul, 06591, Republic of Korea.
Shih-Kien DjengProton Therapy Pte Ltd., 1 Biopolis Drive, Singapore, 138622, Singapore.
Hajime MonzenDepartment of Medical Physics, Graduate School of Medical Sciences, Kindai University, Osaka-Sayama-Shi, 377-2, Ohno-Higashi, Osaka-Sayama-Shi, Osaka, 589-8511, Japan. hmon@med.kindai.ac.jp.
Tae Suk SuhDepartment of Biomedical Engineering and Research Institute of Biomedical Engineering, College of Medicine, The Catholic University of Korea, Seoul, 06591, Republic of Korea. suhsanta@catholic.ac.kr.

Funding

National Research Foundation of Korea 2018A2B2005343
6 · The paper itself

Abstract

backgroundAn O-ring gantry-type linear accelerator (LINAC) with a 6-MV flattening filter-free (FFF) photon beam, Halcyon, includes a reference beam that contains representative information such as the percent depth dose, profile and output factor for commissioning and quality assurance. However, because it does not provide information about the field size, we proposed a method to determine all field sizes according to all depths for radiation therapy using simplified sigmoidal curve fitting (SCF).

methodsAfter mathematical definition of the SCF using four coefficients, the defined curves were fitted to both the reference data (RD) and the measured data (MD). For good agreement between the fitting curve and the profiles in each data set, the field sizes were determined by identifying the maximum point along the third derivative of the fitting curve. The curve fitting included the field sizes for beam profiles of 2 × 2, 4 × 4, 6 × 6, 8 × 8, 10 × 10, 20 × 20 and 28 × 28 cm

resultsAll fitting curves show goodness of fit, R

conclusionApplication of the SCF method has been proven to accurately capture the field size of the preconfigured RD and the measured FFF photon beam data for the Halcyon system. The current work can be useful for beam commissioning as a countercheck methodology to determine the field size from RD in the treatment planning system of a newly installed Halcyon system and for routine quality assurance to ascertain the correctness of field sizes for clinical use of the Halcyon system.

Indexed as

Particle AcceleratorsQuality Assurance, Health CareHumansPhotonsRadiotherapy Planning, Computer-AssistedCommissioningFFFField sizeHalcyonQASigmoidal curve fitting

Identifiers

PMID33287828
PMCPMC7720380

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.