ArticleTechnology in cancer research & treatment
The Potential Role of Intensity-Modulated Proton Therapy in Hepatic Carcinoma in Mitigating the Risk of Dose De-Escalation.
Article in Technology in cancer research & treatment. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 4 citations in OpenAlex.
- Potential of isotoxic dose escalation with robustly optimized VMAT and IMPT for large hepatocellular carcinoma according to baseline liver function.Journal of applied clinical medical physics · 2026Article
- High dose proton and photon-based radiation therapy for 213 liver lesions: a multi-institutional dosimetric comparison with a clinical perspective.La Radiologia medica · 2024Article
- Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeTo investigate the role of intensity-modulated proton therapy (IMPT) for hepatocellular carcinoma (HCC) patients to be treated with stereotactic body radiation therapy (SBRT) in a risk-adapted dose prescription regimen.
methodsA cohort of 30 patients was retrospectively selected as "at-risk" of dose de-escalation due to the proximity of the target volumes to dose-limiting healthy structures. IMPT plans were compared to volumetric modulated arc therapy (VMAT) RapidArc (RA) plans. The maximum dose prescription foreseen was 75 Gy in 3 fractions. The dosimetric analysis was performed on several quantitative metrics on the target volumes and organs at risk to identify the relative improvement of IMPT over VMAT and to determine if IMPT could mitigate the need of dose reduction and quantify the consequent potential patient accrual rate for protons.
resultsIMPT and VMAT plans resulted in equivalent target dose distributions: both could ensure the required coverage for CTV and PTV. Systematic and significant improvements were observed with IMPT for all organs at risk and metrics. An average gain of 9.0 ± 11.6, 8.5 ± 7.7, 5.9 ± 7.1, 4.2 ± 6.4, 8.9 ± 7.1, 6.7 ± 7.5 Gy was found in the near-to-maximum doses for the ribs, chest wall, heart, duodenum, stomach and bowel bag respectively. Twenty patients violated one or more binding constraints with RA, while only 2 with IMPT. For all these patients, some dose de-intensification would have been required to respect the constraints. For photons, the maximum allowed dose ranged from 15.0 to 20.63 Gy per fraction while for the 2 proton cases it would have been 18.75 or 20.63 Gy.
conclusionThe results of this in-silico planning study suggests that IMPT might result in advantages compared to photon-based VMAT for HCC patients to be treated with ablative SBRT. In particular, the dosimetric characteristics of protons may avoid the need for dose de-escalation in a risk-adapted prescription regimen for those patients with lesions located in proximity of dose-limiting healthy structures. Depending on the selection thresholds, the number of patients eligible for treatment at the full dose can be significantly increased with protons.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.