Evidence map›Paper›PMID 33284717›Full record

Observational studyThe Journal of international medical research2020

Evaluation of transmitted glow point at

Eunyoung Cho, Hyun-Chang Kim, Jung-Man Lee, Ji-Hoon Park, Najeong Ha, Ji Hee Hong, Jiwon Lee

Registry-linked trialAbstract readObservational Study
In one paragraph

Observational study in The Journal of international medical research, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT03480035 (Ideal Point of Transluminal Light in Tracheal Intubation With a Light Wand), which is not on this map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT03480035 completednot on this map

Ideal Point of Transluminal Light in Tracheal Intubation With a Light Wand

TypeobservationalSponsorKeimyung University Dongsan Medical CenterRan2018 to 2018Enrolled107ConditionsNeck Disease, Trismus, Tooth AbnormalitiesArmslightwand intubation
3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Eunyoung ChoDepartment of Anesthesiology and Pain Medicine, Keimyung University Dongsan Hospital, Keimyung University School of Medicine, Daegu, Korea.
Hyun-Chang KimDepartment of Anesthesiology and Pain Medicine, Yonsei University College of Medicine, Gangnam Severance Hospital, Seoul, Korea.ORCID https://orcid.org/0000-0001-7783-7595
Jung-Man LeeDepartment of Anesthesiology and Pain Medicine, SMG-SNU Boramae Medical Center, Seoul National University College of Medicine, Seoul, Korea.
Ji-Hoon ParkDepartment of Anesthesiology and Pain Medicine, Keimyung University Dongsan Hospital, Keimyung University School of Medicine, Daegu, Korea.
Najeong HaDepartment of Anesthesiology and Pain Medicine, Keimyung University Dongsan Hospital, Keimyung University School of Medicine, Daegu, Korea.
Ji Hee HongDepartment of Anesthesiology and Pain Medicine, Keimyung University Dongsan Hospital, Keimyung University School of Medicine, Daegu, Korea.
Jiwon LeeDepartment of Anesthesiology and Pain Medicine, Keimyung University Dongsan Hospital, Keimyung University School of Medicine, Daegu, Korea.ORCID https://orcid.org/0000-0002-6650-0396

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveWhen performing lightwand intubation, an improper transmitted glow position before tube advancement can cause intubation failure or laryngeal injury. This study was performed to explore the transmitted glow point corresponding to

methodsBefore lightwand intubation, we marked the transmitted glow point from a bronchoscope on the neck when it reached 1 cm below the vocal cords. Lightwand intubation was then performed using this marking point. The distances from the mark to the upper border of the thyroid cartilage, upper border of the cricoid cartilage, and suprasternal notch were measured.

resultsIn total, 107 patients were enrolled. The success rate of lightwand intubation using the mark was 93.5% (95% confidence interval, 88.7%-99.2%) at the first attempt. The marking point was placed 12.0 mm (95% confidence interval, 10.6-13.4 mm) below the upper border of the cricoid cartilage.

conclusionAnaesthesiologists should be aware of the appropriate point of the transmitted glow on the patient's neck when performing lightwand intubation. We suggest that this point is approximately 1 cm below the upper border of the cricoid cartilage.Trial registration: ClinicalTrials.gov NCT03480035.

Indexed as

Intubation, IntratrachealVocal CordsHumansNeckProspective Studiesbronchoscopecricoid cartilagegeneral anaesthesiaIntubationlightwandtransmitted glow

Identifiers

PMID33284717
PMCPMC7724411

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.