Evidence map›Paper›PMID 33283144›Full record

ArticleEuropean journal of hybrid imaging2019

Assessment of a novel 32-channel phased array for cardiovascular hybrid PET/MRI imaging: MRI performance.

Adam Farag, R Terry Thompson, Jonathan D Thiessen, John Butler, Frank S Prato, Jean Théberge

Open access · goldAbstract read
In one paragraph

Article in European journal of hybrid imaging, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.2field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 7 citations in OpenAlex.

  1. Mouse Cardiovascular Imaging.Current protocols · 2024
    Review
  2. Article
  3. Hybrid PET/MR imaging in myocardial inflammation post-myocardial infarction.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2020
    Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Adam FaragLawson Health Research Institute, Imaging Division, 268 Grosvenor St., Rm E5-118, PO Box 5777, STN B, London, ON N6A 4V2 Canada.
R Terry ThompsonLawson Health Research Institute, Imaging Division, 268 Grosvenor St., Rm E5-118, PO Box 5777, STN B, London, ON N6A 4V2 Canada.
Jonathan D ThiessenLawson Health Research Institute, Imaging Division, 268 Grosvenor St., Rm E5-118, PO Box 5777, STN B, London, ON N6A 4V2 Canada.
John ButlerLawson Health Research Institute, Imaging Division, 268 Grosvenor St., Rm E5-118, PO Box 5777, STN B, London, ON N6A 4V2 Canada.
Frank S PratoLawson Health Research Institute, Imaging Division, 268 Grosvenor St., Rm E5-118, PO Box 5777, STN B, London, ON N6A 4V2 Canada.
Jean ThébergeLawson Health Research Institute, Imaging Division, 268 Grosvenor St., Rm E5-118, PO Box 5777, STN B, London, ON N6A 4V2 Canada.
Western University · CALawson Health Research Institute · CA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundCardiovascular imaging using hybrid positron emission tomography (PET) and magnetic resonance imaging (MRI) requires a radio frequency phased array resonator capable of high acceleration factors in order to achieve the shortest breath-holds while maintaining optimal MRI signal-to-noise ratio (SNR) and minimum PET photon attenuation. To our knowledge, the only two arrays used today for hybrid PET/MRI cardiovascular imaging are either incapable of achieving high acceleration or affect the PET photon count greatly. PURPOSE: This study is focused on the evaluation of the MRI performance of a novel third-party prototype 32-channel phased array designed for simultaneous PET/MRI cardiovascular imaging. The study compares the quality parameters of MRI parallel imaging, such as g-factor, noise correlation coefficients, and SNR, to the conventional arrays (mMR 12-channel and MRI-only 32-channel) currently used with hybrid PET/MRI systems. The quality parameters of parallel imaging were estimated for multiple acceleration factors on a phantom and three healthy volunteers. Using a Germanium-68 (Ge-68) phantom, preliminary measurements of PET photon attenuation caused by the novel array were briefly compared to the photon counts produced from no-array measurements.

resultsThe global mean of the g-factor and SNR

conclusionsThe MRI performance of the novel PET/MRI 32-channel array qualifies it to be a viable alternative to the conventional arrays for cardiovascular hybrid PET/MRI. A detailed evaluation of the novel array's PET performance remains to be conducted, but cursory assessment promises significantly reduced attenuation.

Indexed as

Cardiac imagingParallel imagingPET/MRIPhased array

Identifiers

PMID33283144
PMCPMC7717874
OpenAlexW2969372464

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.