Evidence map›Paper›PMID 33282772›Full record

ArticleJournal of International Society of Preventive & Community Dentistry

Comparison of Primary Stability of Implants Installed by Two Different Methods in D3 and D4 Bone Types: An

Vinod Bandela, Bharathi Munagapati, Jayashree Komala, Ram B Basany, Santosh R Patil, Saraswathi Kanaparthi

Open access · greenAbstract read
In one paragraph

Article in Journal of International Society of Preventive & Community Dentistry. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.5field-weighted citation impact, top 35% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Article
  3. Evaluation of Stress Distribution and Force in External Hexagonal Implant: A 3-D Finite Element Analysis.International journal of environmental research and public health · 2021
    Article
  4. The Influence of Implant Macro-geometry in Primary Stability in Low-Density Bone: AnJournal of International Society of Preventive & Community Dentistry
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 5 institutions in 1 country.

Vinod BandelaFaculty of Dentistry, Pacific Academy of Higher Education and Research University, Udaipur, Rajasthan, 313003, India.
Bharathi MunagapatiDepartment of Prosthodontics and Crown & Bridge, G. Pulla Reddy Dental College & Hospital, Kurnool, Andhra Pradesh, 518002, India.
Jayashree KomalaDepartment of Prosthodontics and Crown & Bridge, SVS Institute of Dental Sciences, Mahabubnagar, Telangana, 522660, India.
Ram B BasanyDepartment of Prosthodontics and Crown & Bridge, SVS Institute of Dental Sciences, Mahabubnagar, Telangana, 522660, India.
Santosh R PatilDepartment of Oral Medicine and Radiology, New Horizon Dental College and Research Institute, Bilaspur, Chhattisgarh, 495001, India.
Saraswathi KanaparthiDepartment of Pedodontics and Preventive Dentistry, St. Joseph Dental College and Hospital, Eluru, Andhra Pradesh, 534004, India.
SVS Medical College · INChhattisgarh Dental College & Research Institute · ING Pulla Reddy Dental College & Hospital · INPacific Dental College and Hospital · INSt. Joseph Dental College · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveThe purpose of the study is to assess the method of implant insertion in D3 and D4 bones and influence of insertion torque for achieving better primary implant stability. MATERIALS AND

methodsA total of 32 specimens (wood blocks) simulating D4 and D3 bone were grouped into 1, 2, 3, and 4. In groups 1 and 3, the implant and abutment were placed by manual method while in groups 2 and 4 by motor-driven method. The osteotomy site was prepared as per the protocol for soft bone, and implants were placed till the implant platform was in flush with the surface of the block. After achieving a standard insertion torque of 40 N.cm, pullout test was carried out with a universal testing machine and results were analyzed by one-way analysis of variance.

resultsAn intergroup comparison of peak loads revealed an overall statistically significant difference (

conclusionThe D3 bone sample provided greater primary stability of implant than D4 bone samples, and the motor-driven implant seemed to have improved stability than that placed manually.

Indexed as

D3 boneD4 boneimplant insertionprimary stabilitypullout forceYoung’s modulus

Identifiers

PMID33282772
PMCPMC7685276
OpenAlexW3091135793

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.