Trial reportClinical and translational science2021
Clinical Evaluation of an Investigational 5 mL Wearable Injector in Healthy Human Subjects.
Trial report in Clinical and translational science, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 17 citations in OpenAlex.
- Yushida: an IoT-based smart injection system for long-term management of chronic diseases.Frontiers in digital health · 2026Review
- Artificial Intelligence-Driven Wearable and Connected Technology for Allergy: Real-Time Monitoring and Predictive Management for Personalized Care.The journal of allergy and clinical immunology. In practice · 2025Review
- Advancing Subcutaneous Dosing Regimens for Biotherapeutics: Clinical Strategies for Expedited Market Access.BioDrugs : clinical immunotherapeutics, biopharmaceuticals and gene therapy · 2024Review
- Investigation into the Acceptability of Moderate-to-Large Volume Subcutaneous Injections in Healthy Volunteers: Results from a Single-Center Randomized Controlled Study.Medical devices (Auckland, N.Z.) · 2024Article
- Imaging of large volume subcutaneous deposition using MRI: exploratory clinical study results.Drug delivery and translational research · 2023Article
- Characterization of large volume subcutaneous injections using computed tomography imaging and simultaneous pressure measurements.Frontiers in drug delivery · 2023Article
- Clinical evaluation of large volume subcutaneous injection tissue effects, pain, and acceptability in healthy adults.Clinical and translational science · 2022Article
- Formative Study on the Wearability and Usability of a Large-Volume Patch Injector.Medical devices (Auckland, N.Z.) · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 4 institutions in 3 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
An investigational wearable injector (WI), the BD Libertas Wearable Injector (BD Libertas is a trademark of Becton, Dickinson and Company), was evaluated in an early feasibility clinical study for functional performance, tissue effects, subject tolerability, and acceptability of 5 mL, non-Newtonian ~ 8 cP subcutaneous placebo injections in 52 healthy adult subjects of 2 age groups (18-64 years and ≥ 65 years). Randomized WI subcutaneous injections (n = 208, 4/subject) were delivered to the right and left abdomen and thigh of each subject, 50% (1 thigh and 1 abdomen) with a defined movement sequence during injection. Injector functional performance was documented. Deposition was qualified and quantified with ultrasound. Tissue effects and tolerability (pain) were monitored through 24 hours with corresponding acceptability questionnaires administered through 72 hours. WI (n = 205) automatically inserted the needle, delivered 5 mL ± 5% in 5.42 minutes (SD 0.74) and retracted. Depots were entirely (93.2%) or predominantly (5.4%) localized within the target subcutaneous tissue. Slight to moderate wheals (63.9%) and erythema (75.1%) were observed with ≥ 50% resolution within 30-60 minutes. Subject pain (100 mm Visual Analog Scale) peaked mid-injection (mean 9.1 mm, SD 13.4) and rapidly resolved within 30 minutes (mean 0.4 mm, SD 2.6). Subjects' peak pain (≥ 90.2%), injection site appearance (≥ 92.2%) and injector wear, size, and removal (≥ 92.1%) were acceptable (Likert responses) with 100% likely to use the injector if prescribed. Injection site preference was divided between none (46%), abdomen (25%), or thigh (26.9%). The investigational WI successfully delivered 5 mL viscous subcutaneous injections. Tissue effects and pain were transient, well-tolerated and acceptable. Neither injection site, movement or subject age affected injector functional performance or subject pain and acceptability.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials