Evidence map›Paper›PMID 33275114›Full record

ArticleJournal of medical Internet research2020

Open-Source Technology for Real-Time Continuous Glucose Monitoring in the Neonatal Intensive Care Unit: Case Study in a Neonate With Transient Congenital Hyperinsulinism.

Katarina Braune, Mandy Wäldchen, Klemens Raile, Sigrid Hahn, Tebbe Ubben, Susanne Römer, Daniela Hoeber, Nora Johanna Reibel, Michael Launspach, Oliver Blankenstein and 1 more

Open access · goldAbstract readCase Reports
In one paragraph

Article in Journal of medical Internet research, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
1.6field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 13 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors at 3 institutions in 2 countries.

Katarina BrauneCharité - Universitätsmedizin Berlin, Department of Paediatric Endocrinology and Diabetes, Berlin, Germany.ORCID 0000-0001-6590-245X
Mandy WäldchenSchool of Sociology, University College Dublin, Belfield, Ireland.ORCID 0000-0003-0404-517X
Klemens RaileCharité - Universitätsmedizin Berlin, Department of Paediatric Endocrinology and Diabetes, Berlin, Germany.ORCID 0000-0002-0842-1737
Sigrid HahnCharité - Universitätsmedizin Berlin, Department of Neonatology, Berlin, Germany.ORCID 0000-0003-2604-7176
Tebbe Ubben#dedoc° Diabetes Online Community, Dedoc Labs GmbH, Berlin, Germany.ORCID 0000-0003-2573-2198
Susanne RömerCharité - Universitätsmedizin Berlin, Department of Neonatology, Berlin, Germany.ORCID 0000-0001-5568-8509
Daniela HoeberCharité - Universitätsmedizin Berlin, Department of Paediatric Gastroenterology, Nephrology and Metabolic Diseases, Berlin, Germany.ORCID 0000-0003-4106-3545
Nora Johanna ReibelCharité - Universitätsmedizin Berlin, Department of Neonatology, Berlin, Germany.ORCID 0000-0002-6412-4606
Michael LaunspachBerlin Institute of Health, Berlin, Germany.ORCID 0000-0001-5337-5605
Oliver BlankensteinCharité - Universitätsmedizin Berlin, Institute for Experimental Paediatric Endocrinology, Berlin, Germany.ORCID 0000-0003-1803-5589
Christoph BührerCharité - Universitätsmedizin Berlin, Department of Neonatology, Berlin, Germany.ORCID 0000-0002-9950-414X
Charité - Universitätsmedizin Berlin · DEBerlin Institute of Health at Charité - Universitätsmedizin Berlin · DEUniversity College Dublin · IE

Funding

Wellcome Trust
6 · The paper itself

Abstract

backgroundUse of real-time continuous glucose monitoring (rtCGM) systems has been shown to be a low-pain, safe, and effective method of preventing hypoglycemia and hyperglycemia in people with diabetes of various age groups. Evidence on rtCGM use in infants and in patients with conditions other than diabetes remains limited.

objectiveThis case study describes the off-label use of rtCGM and the use of an open-source app for glucose monitoring in a newborn with prolonged hypoglycemia secondary to transient congenital hyperinsulinism during the perinatal period.

methodsThe Dexcom G6 rtCGM system (Dexcom, Inc) was introduced at 39 hours of age. Capillary blood glucose checks were performed regularly. In order to benefit from customizable alert settings and detect hypoglycemic episodes, the open-source rtCGM app xDrip+ was introduced at 9 days of age.

resultsTime in range (45-180 mg/dL) for interstitial glucose remained consistently above 90%, whereas time in hypoglycemia (<45 mg/dL) decreased. Mean glucose was maintained above 70 mg/dL at 72 hours of life and thereafter. Daily sensor glucose profiles showed cyclic fluctuations that were less pronounced over time.

conclusionsWhile off-label use of medication is both common practice and a necessity in newborn infants, there are few examples of off-label uses of medical devices, rtCGM being a notable exception. Real-time information allowed us to better understand glycemic patterns and to improve the quality of glycemic control accordingly. Severe hypoglycemia was prevented, and measurement of serum levels of insulin and further lab diagnostics were performed much faster, while the patient's individual burden caused by invasive procedures was reduced. Greater customizability of threshold and alert settings would be beneficial for user groups with glycemic instability other than people with diabetes, and for hospitalized newborn infants in particular. Further research in the field of personal and off-label rtCGM use, efficacy studies evaluating the accuracy of low glucose readings, and studies on the differences between algorithms in translating raw sensor data, as well as customization of commercially available rtCGM systems, is needed.

Indexed as

Blood GlucoseBlood Glucose Self-MonitoringCongenital HyperinsulinismFemaleHumansInfant, NewbornIntensive Care Units, NeonatalMaleBlood Glucosecongenital hyperinsulinismcontinuous glucose monitoringmobile healthneonatal hypoglycemiaoff-label useopen-sourcetransient hyperinsulinism

Identifiers

PMID33275114
PMCPMC7748959
OpenAlexW3095220280

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.