Evidence map›Paper›PMID 33274607›Full record

ArticleOrthopaedic surgery2021

The Effect of a PEEK Material-Based External Fixator in the Treatment of Distal Radius Fractures with Non-Transarticular External Fixation.

Mao Xie, Yinghao Cao, Xianyi Cai, Zengwu Shao, Ke Nie, Liming Xiong

Abstract readComparative Study
In one paragraph

Article in Orthopaedic surgery, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Trial
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Mao Xie *Department of Orthopaedic, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
Yinghao Cao *Department of Gastrointestinal Surgery, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
Xianyi CaiDepartment of Orthopaedic, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
Zengwu ShaoDepartment of Orthopaedic, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
Ke NieDepartment of Orthopaedic Surgery, Zhijiang People's Hospital, Zhijiang, China.
Liming XiongDepartment of Orthopaedic, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.ORCID https://orcid.org/0000-0002-2563-3256

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo explore the effect of a PEEK material-based external fixator in the treatment of distal radius fractures with non-transarticular external fixation.

methodsThere were 48 patients in this prospective comparative study. They were divided into two groups according to the materials used: the PEEK group and the titanium group. Wrist dorsiflexion, palmar flexion, pronation, supination, radial deviation, ulnar deviation, grip strength of the palm on the affected side, kneading force, Visual Analogue Scale/Score (VAS), Disabilities of the Arm, Shoulder, and Hand (DASH) score, operation time, frequency of fluoroscopy procedures, and X-ray results were compared between the two groups. Functional recovery was evaluated at the last follow-up according to the wrist joint evaluation criteria.

resultsThe baseline data were comparable between the two groups, and no significant differences were found in age, sex, fracture types (P > 0.05). There was no significant difference between the two groups in the results of DASH, grip strength, and recovery of pinch force and wrist function (dorsiflexion, clavicle, ulnar deviation, deviation, pronation, and supination) (P > 0.05). Normal limb function was achieved in the two groups of patients at an average of 6 weeks after surgery, and there was no significant difference in X-ray examination radial height (10.60 ± 1.59 vs 11.00 ± 1.53, P = 0.687), radial inclination (1.11 ± 0.24 vs 1.12 ± 0.24, P = 0.798), volar tilt (10.33 ± 2.13 vs 10.00 ± 2.08, P = 0.660), ulnar variance (20.87 ± 3.00 vs 20.38 ± 3.04, P = 0.748), and step-off persistence (1.73 ± 0.69 vs 1.68 ± 0.72, P = 0.425) between the two groups (P > 0.05). However, the operation time (54.80 ± 12.20 vs 85.23 ± 15.14, P = 0.033) and number of fluoroscopy procedures (36.93 ± 6.89 vs 64.77 ± 9.74, P = 0.000) in the PEEK group were significantly reduced compared with those in the titanium group.

conclusionCompared with the traditional titanium external fixator, the PEEK composite external fixator has advantages, such as a shorter operation time and fewer fluoroscopy procedures when used to treat different types of distal radius fracture.

Indexed as

Equipment DesignExternal FixatorsAdultAgedBenzophenonesDisability EvaluationFemaleFracture FixationHumansMaleMiddle AgedPain MeasurementPolymersProspective StudiesRadius FracturesRange of Motion, ArticularBenzophenonespolyetheretherketonePolymersTitaniumBiomaterialsDistal radius fracturesExternal fixationPEEK

Identifiers

PMID33274607
PMCPMC7862170

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.