ArticleJournal of applied clinical medical physics2020
Using flattening filter free beams in electronic tissue compensation whole breast irradiation with deep inspiration breath hold.
Article in Journal of applied clinical medical physics, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 1 citations in OpenAlex.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeIn order to reduce heart dose, DIBH has become a common practice in left-sided whole breast irradiation. This technique involves a significant strain on patients due to the breath-hold requirements. We hereby investigate the dosimetric and delivery feasibility of using flattening filter free (FFF) energies with electronic tissue compensation (ECOMP) planning technique to reduce the required breath-hold lengths and increase patient compatibility.
methodsFifteen left-sided, postlumpectomy patients previously receiving DIBH whole-breast radiotherapy (266cGy x 16fx) were retrospectively planned using ECOMP for both 6X and 6X-FFF. A dosimetric comparison was made between the two plans for each patient using various dosimetric constraints. Delivery feasibility was analyzed by recalculating the 6X ECOMP plan with 6X-FFF without replanning (6X-FFF QA) and delivering both plans for a one-to-one comparison using Gamma analysis. Beam-on times for the 6X and 6X-FFF plans were measured. For all tests, Wilcoxon signed-rank test was used with P < 0.05 as significant.
resultsNo statistical difference was observed between 6X and 6X-FFF plans for most dosimetric endpoints except contralateral breast D
conclusionECOMP planning with FFF was found feasible for left-sided breast patients with DIBH. Plan quality is comparable, if not better, than plans using flattened beams. FFF ECOMP could significantly reduce beam-on time and required breath-hold lengths thereby increasing patient compatibility for this treatment while offering satisfactory plan quality and delivery accuracy.